![background image](http://html.mh-extra.com/html/pro-point/8630790/8630790_user-manual_1607393016.webp)
8630790
6 in. Composite Orbital Air Palm Sander
V1.0
PROBLEM(S)
POSSIBLE CAUSE(S)
SUGGESTED
SOLUTION(S)
Decreased output.
1. Not enough air
pressure and/or
air flow.
1. Check for loose
connections and make
sure that the air supply
is providing enough air
flow (CFM) at the
required pressure (PSI)
to the tool’s air inlet.
WARNING! Do not
exceed the maximum
air pressure of 90 PSI.
2. Obstructed throttle. 2. Clean around
the throttle to ensure
free movement.
3. Incorrect
lubrication or not
enough lubrication.
3. Lubricate using air
tool oil and grease
according to directions.
4. Blocked air inlet
screen (if equipped).
4. Clean the air inlet
screen of buildup.
5. Air leaking from
loose housing.
5. Make sure that the
housing is properly
assembled and tight.
6. Mechanism
is contaminated.
6. Have a qualified
service technician clean
and lubricate the
mechanism. Install and
in-line filter in the air
supply line.
7. Clogged muffler
filter (if attached).
7. Remove and
wash/replace the
muffler filter.
16