![background image](http://html.mh-extra.com/html/pro-point/8553521/8553521_user-manual_1607345009.webp)
V1.0
6,000W SHOP HEATER
8553521
Visit www.princessauto.com for more information
9
1. Position the unit to cover the desired area.
1.1 Rotate the unit on the hanging bracket.
1.2 Loosen the tilt adjustable knob (B) and tilt the unit.
Retighten the knob.
1.3 Adjust the louvers (D) to direct the air flow.
2. Power the unit ON by pushing the breaker switch to the
active position.
3. Press the rocker switch (H) to either low (3,000W) or
high (6,000W).
4. Turn the temperature setting knob (I) to the highest level.
The fan will blow the heated air into the room. When the
room temperature is comfortable, slowly turn the knob
counterclockwise until the heater shuts OFF. The heater will
automatically restart when the room temperature drops
below this set point.
5. Trip the circuit breaker to turn the heater OFF.
OVERHEAT ALARM
The unit has a thermal cut-off protection switch that will trip if
the unit overheats. The alarm LED (G) will also flash. Trip the
circuit breaker to shut the unit OFF. Wait for the unit to cool for
10 minutes.
Inspect surrounding structure adjacent to the heater for
damage. Also check to ensure there is nothing around the unit
that could trap heat and cause the overheating.
Flip the circuit breaker to the active setting and wait for the
unit to heat up. Consult with a qualified electrician if the
thermal cut-off protection trips again.