background image

 

 

CONGRATULATIONS

 

The  Marquee-Lite

 

PLUS 

is  the  finest  retrofit  messaging  center  available  on  the  market 

today.  The Marquee-Lite

 Plus (ML+) is designed for ease of use, ease of installation, and 

years of trouble free service. 
 

CABINET INSTALLATION 

These displays are designed to fit into an 8 foot cabinet. In some cases you may install the 
unit(s) in a larger cabinet, but suitable filler panels will need to be fabricated. Your ML+ is 
designed to slide into a standard cabinet, with a 2” flange or less. If the ML+ does not take 
up the whole cabinet space, a divider bar and filler panel must be fabricated. This is usually 
a  sign  face  made  of  polycarbonate,  and  is  included  with  most  retrofit  kits.  Please  contact 
your local sign fabricator if you do not have this solution. 
 

 

OVERHEATING/CONDENSTATION WARNING 

Vents for retrofits is a MUST! Water-proof vents must be installed on the sides of the cabinet 
toward the top end. The ML+ can already dissipate heat from its own casing via the built-in 
fans, but the cabinet enclosure must allow for that heat to escape as needed. 
Vents installation also prevent condensation build-up on the plexi. If the air is cold outside 
while the air is warm inside, this will cause the plexi to fog up. The vents help by allowing 
fresh air to be circulated.  Sign damage from overheating or condensation is not covered 
under the warranty.

 

 

 

ELECTRICAL DANGER 

Do not allow AC power to be connected inadvertently during installation. Make sure all 
connections are correct and secure by reviewing the installation manual before turning ON 
the AC power. Do not make modifications while sign is in operation.

 

 
BEFORE INSTALLATION

 

 

Make sure all the content in this manual is read and understood. 

 

Follow all warnings and instructions indicated in this manual including those marked 
on the product. 

 

Make sure installation meets all local and state codes. 

 

Installer will assume all responsibility for installation and structural integrity. 

 

MAINTAINING PRODUCT WARRANTY 

 

Do not open, modify or disassemble any part of the unit. This will void warranty and 
may result in electrical shock and/or serious injury. 

 

Water-proof vents must be installed for retrofits. 

 

Retrofits must prevent water from entering the cabinet during wet weather.   

 

Retain manual for future reference. 

 
 

 

 
 
 
 
 

Summary of Contents for Marquee-Lite Plus 4025

Page 1: ...1 Model 4025...

Page 2: ...heat to escape as needed Vents installation also prevent condensation build up on the plexi If the air is cold outside while the air is warm inside this will cause the plexi to fog up The vents help...

Page 3: ...3 PACKING LIST 4 5 SIGN CONFIGURATION 6 7 SIGN COMMUNICATION OPTIONS 8 SIGN COMMUNICATION 9 12 TEMPERATURE SENSOR INSTALLATION 13 AC POWER CONNECTION 14 CUSTOMER SERVICE 15...

Page 4: ...4 SIGN Data Cable 1 per sign Temperature Sensor Case Installation Manual Software Manual Wireless Transmitter Kit REFER TO NEXT PAGE...

Page 5: ...PE B VW321B Wireless USB Transceiver Computer Side x 1 Wireless COM Transceiver Sign Side x 1 USB Cable x 1 Antenna x 2 Antenna Mounts x 2 Power Supply x 1 Power cable for COM Transceiver x1 Wireless...

Page 6: ...have to be configured as a MASTER 1 Locate the MASTER INPUT and OUTPUT1 ports on the back left side of the sign 2 Using the supplied Data Cable connect as shown below 3 Secure the connections by tight...

Page 7: ...be configured as MASTER or a SLAVE It is important to note that the MASTER will always be the primary signal carrier 1 Now connect the remaining Data Cable as shown below 2 Secure all connections by...

Page 8: ...gn and the sign will be instantly updated During installation make sure the USB Cable is available to the user for access Do not leave USB connection exposed to weather environments Recommended that a...

Page 9: ...The transceiver is not weatherproof ANTENNA Antennas from both transceivers must be in line of site with one another for optimal reception It is ok to expose the ANTENNA portion to weather elements a...

Page 10: ...le CP210x_VCP_Win_XP_S2K3_Vista_7 EXE to launch the installation wizard During installation leave all settings at default and follow the prompts to complete the installation Do not proceed to next ste...

Page 11: ...OM PORT number for the transceiver _______________________ If the Wireless USB Transceiver is connected to a different USB port than the last time the COM PORT number will change 11 Install the antenn...

Page 12: ...ansceiver c Now connect the red wire to V and the black wire to V on the sign s DC power supply d On Type A transceiver models connect the transceiver s 9 pin connector to the sign s 9 pin connector O...

Page 13: ...elow the unit s In a retrofit the case must reside outside the cabinet below the units This will require for a hole to be drilled on the bottom of the cabinet so that the temperature sensor cable can...

Page 14: ...er Connect the outlet plug included to a 110VAC wall outlet or splice the plug and hard wire directly to a 110VAC power source using wire nuts not included Your Sign is now ready for operation Please...

Page 15: ...ged for parts and labor The customer shall be solely responsible for failure of any PRO LITE INC product or component thereof resulting from accident abuser misapplication of the product and PRO LITE...

Reviews: