The temperature sensor is located besides the USB and COM cables. 
 
 
 
 
 
 
 
 
 

 

 

 

In a MASTER/SLAVE Configuration, the temperature sensor on the MASTER unit will be the only 
temperature sensor that is required to be installed. The temperature sensor on the SLAVE unit 
can be tucked away. 

 
1) Install the temperature sensor cage so that it sits below the unit(s). 
 

 

In a retrofit, the case must reside outside the cabinet below the units. This will require for a hole 
to be drilled on the bottom of the cabinet so that the temperature sensor cable can be passed 
through. Complete the pass-through by sealing  the hole with silicone. 

 
2) Remove the screw from the temperature sensor. 

     

 

 
3) Feed the temperature sensor into the temperature case. 
 
4) The temperature sensor will be suspended in the center of the cage by securing it in place 
     with the screw. 
 

MASTER ML+ (Backside) 

Temperature Sensor. 

Summary of Contents for Marquee-Lite Plus 4025

Page 1: ...1 Model 4025...

Page 2: ...heat to escape as needed Vents installation also prevent condensation build up on the plexi If the air is cold outside while the air is warm inside this will cause the plexi to fog up The vents help...

Page 3: ...3 PACKING LIST 4 5 SIGN CONFIGURATION 6 7 SIGN COMMUNICATION OPTIONS 8 SIGN COMMUNICATION 9 12 TEMPERATURE SENSOR INSTALLATION 13 AC POWER CONNECTION 14 CUSTOMER SERVICE 15...

Page 4: ...4 SIGN Data Cable 1 per sign Temperature Sensor Case Installation Manual Software Manual Wireless Transmitter Kit REFER TO NEXT PAGE...

Page 5: ...PE B VW321B Wireless USB Transceiver Computer Side x 1 Wireless COM Transceiver Sign Side x 1 USB Cable x 1 Antenna x 2 Antenna Mounts x 2 Power Supply x 1 Power cable for COM Transceiver x1 Wireless...

Page 6: ...have to be configured as a MASTER 1 Locate the MASTER INPUT and OUTPUT1 ports on the back left side of the sign 2 Using the supplied Data Cable connect as shown below 3 Secure the connections by tight...

Page 7: ...be configured as MASTER or a SLAVE It is important to note that the MASTER will always be the primary signal carrier 1 Now connect the remaining Data Cable as shown below 2 Secure all connections by...

Page 8: ...gn and the sign will be instantly updated During installation make sure the USB Cable is available to the user for access Do not leave USB connection exposed to weather environments Recommended that a...

Page 9: ...The transceiver is not weatherproof ANTENNA Antennas from both transceivers must be in line of site with one another for optimal reception It is ok to expose the ANTENNA portion to weather elements a...

Page 10: ...le CP210x_VCP_Win_XP_S2K3_Vista_7 EXE to launch the installation wizard During installation leave all settings at default and follow the prompts to complete the installation Do not proceed to next ste...

Page 11: ...OM PORT number for the transceiver _______________________ If the Wireless USB Transceiver is connected to a different USB port than the last time the COM PORT number will change 11 Install the antenn...

Page 12: ...ansceiver c Now connect the red wire to V and the black wire to V on the sign s DC power supply d On Type A transceiver models connect the transceiver s 9 pin connector to the sign s 9 pin connector O...

Page 13: ...elow the unit s In a retrofit the case must reside outside the cabinet below the units This will require for a hole to be drilled on the bottom of the cabinet so that the temperature sensor cable can...

Page 14: ...er Connect the outlet plug included to a 110VAC wall outlet or splice the plug and hard wire directly to a 110VAC power source using wire nuts not included Your Sign is now ready for operation Please...

Page 15: ...ged for parts and labor The customer shall be solely responsible for failure of any PRO LITE INC product or component thereof resulting from accident abuser misapplication of the product and PRO LITE...

Reviews: