© Pro-Ject Audio Systems · Pro-Ject RPM 9 Carbon · Revision 2015.07.10 

 

5

Mounting and connecting the cartridge 

All cartridges with half inch mounting holes can be mounted. Leave the needle's protection cover on, 
fit the cartridge to the headshell by using the supplied screws by passing one screw through each slot 
in the headshell (15). Do not tighten the nuts yet. 

Connect the tonearm wires with the cartridge pins as follows: 

white   

left channel positive (L+) 

red 

 

right channel positive (R+) 

green   

right channel return (R -) 

blue 

 

left channel return (L -) 

The  full  sound  quality  of  the  record  player  can  only  be  achieved  if  the  cartridge  is  adjusted  correctly. 
Particular tools like the Pro-Ject Audio Systems alignment tool are required to accomplish this job properly. 
If you are not well acquainted with the adjustment of cartridges,  please  call  for  the  willing  help  of  your 
Pro-Ject Audio Systems dealer. 

 

Please  note:  adjusting  a  cartridge  and  tonearm  calls  for  the  greatest  care  in  order  to  avoid 
damaging the cartridge or tonearm bearings. Ask your local dealer for help if you are unsure in 
any of the necessary steps and precautions which must be taken. 

Cartridge downforce adjustment 

The supplied counterweights (6) are suitable for cartridges weighing between 5 - 7,5g (counterweight no. 

28

), 7 - 10g (counterweight no. 

46

), 9 - 11g (counterweight no. 

43

) or 10 - 14g (counterweight no. 

29

). Adjust the downforce before installing the anti-skating weight. 

Following adjustments have to be done very carefully Remove cartridge protection cap. Push and turn 
the  counterweight  (6)  carefully  on  the  rear  end  of  the  tonearm  tube  (9),  so  that  the  downforce  scale 
(6a)  shows  towards  the  front  of  the  player.  Lower  the  armlift  and  position  the  cartridge  in  the  space 
between  arm  rest  and  platter.  Rotate  the  counterweight  (6)  until  the  arm  tube  is  balanced.  The  arm 
should return to the balanced position if it is moved up or down.  

Once the arm is balanced correctly return it to the rest. Hold the counterweight (6) without moving it and 
gently revolve the downforce scale ring (6a) until the zero is in line with the anti-skating stub (12). Check 
whether the arm still balances out. 

Rotate  the counterweight counter  clockwise (seen from the front) to  adjust the  downforce  according 
to the cartridge  manufacturer's recommendations. One  mark on  the scale represents 1  mN (= 0,1g / 
0,1 Pond) of downforce. 

Adjusting the vertical tracking angle (vta)

 

Put a record and the record weight on the platter. When the needle is lowered into the record groove and 
the tonearm is not resting on the lift arm, the tube of the tonearm should be parallel to the surface of the 
record.  

If it is not, loosen both hexagon screws in the tonearm base just enough to allow vertical movement of 
the arm pillar without force and slide the arm up or down until it is parallel.  

Retighten the hexagon screws without applying excessive force (which would deform the arm pillar) – 
finger tight is quite sufficient. 

 

Summary of Contents for Pro-Ject RPM 10

Page 1: ...INSTRUCTIONS FOR USE Pro Ject RPM 9 Carbon...

Page 2: ...Pro Ject Audio Systems Pro Ject RPM 9 Carbon Revision 2015 07 10 2...

Page 3: ...t lever 8 18 Tonearm rest and removable transport lock 9 Tonearm tube 9a Tonearm base 10 Power supply socket 11 Phono output through 5 PIN connector 12 Anti skating weight adjustment scale 13 Anti ska...

Page 4: ...lighted candles on or near the device The product shall not be used in damp or wet locations next to a bathtub sink swimming pool or any other similar conditions Keep plastic bags away from children t...

Page 5: ...9 Adjust the downforce before installing the anti skating weight Following adjustments have to be done very carefully Remove cartridge protection cap Push and turn the counterweight 6 carefully on the...

Page 6: ...ng the thread into the groove of the wire support 14 Connection to the amplifier The record player uses an output through a 5 PIN connector 11 Use supplied Pro Ject Connect IT 5P CC cable to connect t...

Page 7: ...lied sparingly to avoid damage to rubber parts It is recommended to fit the needle cover before cleaning or maintenance to avoid damage If the player is not used over a long period of time the drive b...

Page 8: ...atter bearing without oil dirty or damaged Service Should you encounter a problem which you are not able to alleviate or identify despite the above information please contact your dealer for further a...

Page 9: ...Pro Ject Audio Systems Pro Ject RPM 9 Carbon Revision 2015 07 10 9...