Set-up 

The deck is supplied partially disassembled and carefully packaged for safe transport. Carefully remove all 
parts from the transport packaging. 

Make sure the surface you wish to use the turntable on is level (use a spirit level) before placing the turntable on it. 
Remove the transport lock (18) from the tonearm. Store it in the original packaging so it is available for any 
future transportation. 
Fit the flat drive belt (3) around the hub (4) and the smaller diameter part of the motor pulley (2). Avoid 

getting sweat or grease on the belt as these will deteriorate the performance and reduce the belt's lifespan. 
Use absorbent kitchen paper to remove any oil or grease from the outer edge of the hub and the belt. Fit the 
platter (5) over the spindle of the hub (4). 

 

Please note: We recommend to use the record player without a mat on the platter. 

Cartridge downforce adjustment 

The counterweight (6) supplied is suitable for cartridges weighing between 6,5 - 8,5g (weight no. 08). An 
alternative counterweight for cartridges weighing between 4,5 - 6g (weight no. 80) is available as an accessory part. 

Pushing carefully, turn the counterweight (6) onto the rear end of the tonearm tube (9), so that the downforce 
scale (6a) shows towards the front of the player. Lower the armlift and position the cartridge in the space 
between arm rest and platter. Carefully rotate the counterweight (6) until the armtube balances out. The arm 
should return to the balanced position if it is moved up or down. This adjustment must be done carefully. Do 
not forget to remove the cartridge protection cap if fitted. 

Once the arm is correctly balanced return it to the rest. Hold the counterweight (6) without moving it, and gently 
revolve the downforce scale ring (6a) until the zero is in line with the anti-skating stub (15). Check whether the 
arm still balances out. 
Rotate the counterweight counter clockwise (seen from the front) to adjust the downforce according to the cartridge 
manufacturer's recommendations. One mark on the scale represents 1 mN (= 0,1g / 0,1 Pond) of downforce. 

 

Please note: Adjust the downforce prior to installing the anti-skating weight. 
The recommended downforce for the Ortofon 2M Red cartridge is 

17,5mN

Anti-skating force adjustment

 

The anti-skating force must be adjusted corresponding to the downforce as follows: 
Downforce 

 

Groove in the stub (15) 

10 - 14mN 

 

1

st

  from bearing rings 

15 - 19mN 

 

2

nd

    "         "         " 

20mN and bigger

 

3

rd

     "         "         "

 

 

Slip the loop of the anti-skating weight's thread over the second groove of the stub to set the correct anti-

skating force for the factory-fitted cartridge. Feed the thread through the loop of the wire support (17).

 

Connection to the amplifier 

The record player has gold plated female RCA phono sockets (14) so you can substitute the interconnect cables 
supplied with higher quality cables such as the Pro-Ject Connect it interconnect cables for connection to the 
amplifier if you wish. 
Use the Phono input (sometimes labelled gram, disc or RIAA) on your amplifier. Make sure that the phono input 
offers correct matching and amplification for the type of cartridge used. Line inputs (such as CD, Tuner, Tape or 

Video) are not suitable. 
Take care to connect the left and right channels correctly. The right channel is usually marked red, the left 
channel black or white. Check the manual supplied with your amplifier for relevant information. The earthing 
wire of the tonearm lead should be connected to the earth terminal on your amplifier (if provided). 
If your amplifier does not have an input suitable for phono cartridges you will require a separate phono 

amplifier stage for MM or MC cartridges which is then connected between the record player and a free line 
level input of the amplifier. 
For detailed product information regarding Pro-Ject Audio interconnect cables and phono amplifiers please 
refer to the Pro-Ject web site 

www.project-audio.com

 

The recommended load impedance for the factory fitted cartridges is: 

47kohms

/

MM-input

 

Summary of Contents for Debut Carbon Esprit SB

Page 1: ...INSTRUCTIONS FOR USE Pro Ject Debut Carbon Esprit SB ...

Page 2: ... Audio Trade GmbH Pro Ject Debut Carbon Esprit SB Ortofon 2M Red Revision 2013 11 15 2 10 11 12 2 3 4 5 11 11 21 0 30 5 20 8 6 16 6a 18 9 17 15 7 9a 17 22 14 9a 1 1 19 13 STBY 45 33 ...

Page 3: ...with a factory fitted and adjusted cartridge please ignore the cartridge set up instructions unless changing the cartridge at a later date During assembly and adjustment of the deck small parts could be lost if not carefully placed in a suitable receptacle Before starting assembly make yourself acquainted with the parts listed above and correspondingly numbered in the technical drawings above Sepa...

Page 4: ...s out Rotate the counterweight counter clockwise seen from the front to adjust the downforce according to the cartridge manufacturer s recommendations One mark on the scale represents 1 mN 0 1g 0 1 Pond of downforce Please note Adjust the downforce prior to installing the anti skating weight The recommended downforce for the Ortofon 2M Red cartridge is 17 5mN Anti skating force adjustment The anti...

Page 5: ...ull speed is attained the LED 45 stops flashing A long more than three seconds press on the ON OFF switch stops the motor Useful tips The record player should be positioned on a low resonance surface such as wood or multiple layer ply board to avoid structural vibrations disturbing replay Adjusting the azimuth The cartridge needle must be vertical in the record groove in order to trace the groove ...

Page 6: ...cleaning Your record player requires little or no regular maintenance Remove dust with a slightly moistened antistatic cloth Never use a dry cloth because this will create static electricity which attract more dust Antistatic cleaning fluids are available at specialist stores but must be applied sparingly to avoid damage to rubber parts It is recommended to fit the needle cover before cleaning or ...

Page 7: ...tched or dirty platter bearing without oil dirty or damaged Service Should you encounter a problem which you are not able to alleviate or identify despite the above information please contact your dealer for further advice Only when the problem cannot be resolved there should the unit be sent to the responsible distributor in your country Guarantee repairs will only be effected if the unit is retu...

Page 8: ... Audio Trade GmbH Pro Ject Debut Carbon Esprit SB Ortofon 2M Red Revision 2013 11 15 8 Tomearm transport look Lid Platter Accessories Tonearm counterweight Power supply ...