Pro-face ST3200 Series Installation Manual Download Page 10

10

(3) Insert the USB cable into the USB Host 

Interface.

(4) Attach the USB cover to fix the USB 

cable. Insert the USB cover into the tab 
of the USB holder.

• Check the up/down orientation of the 

USB cover to ensure that the USB 
cable is secured properly.

„

Removing the USB Holder

(1) Lift up the tab of the USB holder and 

then remove the USB cover as shown 
below.

(2) After removing the USB cable, remove 

the picks pushing the USB holder from 
both top and bottom.

UL/c-UL Approval

The ST-3200 Series units are UL/c-UL listed 
products.

(UL File No.E220851)

These products conform to the following 
standards:

„

UL508

Industrial Control Equipment

„

CSA-C22.2 No.142-M1987 

 

(c-UL Approval)

Process Control Equipment

<Cautions>

Be aware of the following items when 
building the ST into an end-use product:

• The ST unit’s rear face is not approved as 

an enclosure. When building the ST unit 
into an end-use product, be sure to use an 
enclosure that satisfies standards as the 
end-use product’s overall enclosure.

• The ST unit must be used indoors only.

• Install and operate the ST with its front 

panel facing outwards.

• If the ST is mounted so as to cool itself 

naturally, be sure to install it in a vertical 
panel. Also, it’s recommended that the ST 
should be mounted at least 100mm away 
from any other adjacent structures or 
machine parts. The temperature must be 
checked on the final product in which the 
ST is installed.

• For use on a flat surface of a Type 4X 

(Indoor Use Only) and/or Type 13 Enclo-
sure.

USB Cable

Tab

USB Cover

Tab

USB Cover

Product Model No.

UL/c-UL 

Registration Model No.

AST3201-A1-D24

3580205-01

AST3211-A1-D24

3580205-02

Summary of Contents for ST3200 Series

Page 1: ...fully packed with special attention to quality However should you find anything damaged or missing please contact your local ST distributor immediately About the Manual For the detailed information on ST3000 series refer to the following manual ST3000 Series Hardware Manual Maintenance Troubleshooting ST3000 Series Hardware Manual can be selected from the help menu of GP Pro EX or downloaded from ...

Page 2: ...lug type RS232C is supported E Serial Interface COM2 AST3201 A1 D24 has Dsub 9 pin plug type and supports RS422 RS485 1 AST3211 A1 D24 has Dsub 9 pin socket type and supports RS485 MPI only 1 RS485 is compliant with AST 3201A units with revision code C or later Revision page 11 Front A Rear E D B C Bottom LED ST Status Green lit Normal operation power is ON or OFFLINE operation Orange blinking Dur...

Page 3: ...sulation Resistance DC500V 10MΩ min between charging and FG terminals Physical Surrounding Air Temperature 0 to 50 C 1 1 When using in an environment where the temperature becomes or exceeds 40 C for an extended period of time the screen contrast level may decrease from its original level of brightness Storage Temperature 20 to 60 C Ambient Humidity 10 to 90 RH Wet bulb temperature 39 C max no con...

Page 4: ... isolation unit CA3 ISO232 01 on COM1 COM1 Recommended Cable Connector XM2D 0901 made by OMRON Corp Recommended Jack Screw XM2Z 0073 made by OMRON Corp Recommended Cable Cover XM2S 0913 made by OMRON Corp Interfit Bracket 4 40 inch screws are used Pin RS232C Signal Name Meaning 1 CD Carrier Detect 2 RD RXD Receive Data 3 SD TXD Send Data 4 ER DTR Data Terminal Ready 5 SG Signal Ground 6 DR DSR Dat...

Page 5: ...ame Meaning 1 RDA Receive Data A NC 2 RDB Receive Data B NC 3 SDA Send Data A LINE Line 4 ERA Data Terminal Ready A RS RTS Request to Send 5 SG Signal Ground SG Signal Ground 2 2 In COM2 on the AST3211 A1 D24 the SG and FG terminals are isolated 6 CSB Clear to Send B 5V 5V External Output 3 4 3 The 5V output for Pin 6 is not protected against overcurrent To prevent damage or unit malfunctions use ...

Page 6: ...lation 1 Create a Panel Cut following the dimen sions in the table below 2 Confirm that the installation gasket is attached to the ST unit and then place the ST unit into the Panel from the front It is strongly recommended that you use the installation gasket since it absorbs vibration in addition to repel ling water For the procedure for replacing the installation gasket refer to ST3000 Series Ha...

Page 7: ...nected be sure the wire is grounded 1 Wiring the DC type power supply cable Power Cord Specifications Use copper conductors only Power Connector Plug Specifications The power connector plug is CA5 DCCNM 01 made by Pro face or MSTB2 5 3 ST 5 08 made by Phoenix Contact Insertion Slot Recess Hook the fastener on the Recess Panel Installation Fastener ST Hook and secure the fastener on the panel with ...

Page 8: ...bundled with or kept close to main circuit lines high voltage high current or input output signal lines To reduce noise make the power cord as short as possible If the supplied voltage exceeds the ST unit s range connect a voltage transformer Between the line and the ground be sure to use a low noise power supply If there is an excess amount of noise connect a noise reducing transformer The temper...

Page 9: ...long grounding wire replace the thin wire with a thicker wire and place it in a duct 4 Input Output Signal Line Cautions All ST Input and Output signal lines must be separated from all operating circuit power cables If this is not possible use a shielded cable and ground the shield To prevent the USB cable from coming off Attaching the USB Holder 1 Before starting the procedure lift up the tab on ...

Page 10: ... aware of the following items when building the ST into an end use product The ST unit s rear face is not approved as an enclosure When building the ST unit into an end use product be sure to use an enclosure that satisfies standards as the end use product s overall enclosure The ST unit must be used indoors only Install and operate the ST with its front panel facing outwards If the ST is mounted ...

Page 11: ...n 8 2 52 Nanko higashi Suminoe ku Osaka 559 0031 JAPAN TEL 81 0 6 6613 3116 FAX 81 0 6 6613 5888 http www pro face com Copyright 2006 Digital Electronics Corporation All rights reserved 085886B AST3200 MT01E BTH 2007 7 SS F Inquiry Do you have any questions about difficulties with this product Please access our site anytime that you need help with a solution http www pro face com otasuke Please be...