E-9
RAS Interface (RAS)
Ethernet Interface (10BASE-T)
This interface complies with the IEEE802.3 Ethernet communication standard
(10BASE-T). This interface uses an RJ-45 type modular jack connector (8
points).
CF Card Slot
This slot accepts a CF Card.
USB Interface (USB1, USB2)
This interface is for connecting USB equipment.
Expansion Unit Interface 1 (EXT1)
This interface is used to connect a DIO unit.
Expansion Unit Interface 2 (EXT2)
This interface is a PCMCIA Bus interface.
This is used to connect a PCMCIA unit.
1
9
8
15
Recommended Connector : Dsub 15-pin plug XM2A-1501 <made by OMRON Corp.>
Recommended Cover : Dsub 15-pin Cover XM2S-1513 <made by OMRON Corp.>
Use Jack Screw XM2Z-0073 <made by OMRON Corp.>
when needed.
Pin Arrangement
Pin #
Signal
Condition
1
ALARM-OUT (-)
Alarm Output (-)
2
DOUT (-)
General Purpose Output (-)
3
RESET-IN (-)
Remote Reset Input (-)
4
DIN0 (-)
General Purpose Input 0 (-)*
1
5
DIN1 (-)
General Purpose Input 1 (-)*
1
6
NC
No Contact
7
RESERVE
Reserved
8
RESERVE
Reserved
9
ALARM-OUT (+)
Alarm Output (+)
10
DOUT (+)
General Purpose Output (+)
11
RESET-IN (+)
Remote Reset Input (+)
12
DIN0 (+)
General Purpose Input 0 (+)*
1
13
DIN1 (+)
General Purpose Input 1 (+)*
1
14
RESERVE
Reserved
15
RESERVE
Reserved
*1
General purpose Input will latch Input Information.(This detects only the DIN circuit's ON
state. OFF is not monitored.)