E-6
*1
The front face of the PS-G unit, installed in a solid panel, has been tested using conditions
equivalent to the standard shown in the specification . Even though the PS-G unit’s level of
resistance is equivalent to this standard, oils that should have no effect on the PS-G can
possibly harm the unit. This can occur in areas where either vaporized oils are present, or
where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the
PS-G’s front face protection sheet becomes peeled off, these conditions can lead to the ingress
of oil into the PS-G and separate protection measures are suggested. Also, if non-approved
oils are present, it may cause deformation or corrosion of the front panel’s plastic cover.
Therefore, prior to installing the PS-G be sure to confirm the type of conditions that will be
present in the PS-G’s operating environment.
If the installation gasket is used for a long period of time, or if the unit and its gasket are
removed from the panel, the original level of the protection cannot be guaranteed. To main-
tain the original protection level, Pro-face recommends that you replace the installation gas-
ket regularly.
Structural
Grounding
100
Ω
or less, or your country’s applicable standard
Ratings
*1
(Front face of installed unit)
Equivalent to IP65f (JEM 1030)
Design Type: Modular
Installation method: panel mounting
Cooling Method
Natural air circulation
Weight
Approx. 3.5kg (7.7Ib)
Dimensions (W x H x D)
317 mm [12.48 in] x 243 mm [9.57 in.] x 58 mm [2.28 in.]