In [Convert-To], designate a GP-Pro EX’s project file (*.prx). Click the [Browse…] 
button and enter a new [File Name] (e.g.: “Product system A.prx”). Click [Save], 
and a new project file will be set to [Convert-To]. 

 

 

 

Summary of Contents for GP4000 SERIES

Page 1: ...1 45 Easy Smooth GP 37W2 GP4000 Series Replacement Guidebook 4th Edition 2014 11 Copyright 2014 11 Digital Electronics Corporation All Rights Reserved...

Page 2: ...e Recommended Substitution GP 37W2 GP 4301TW Safety Information HAZARD OF OPERATOR INJURY OR UNINTENDED EQUIPMENT DAMAGE Before operating any of these products be sure to read all related manuals thor...

Page 3: ...3 5 3 GP 4300 series 5 7 4 GP 4400 series 7 5 7 0 W 5 GP 4500 series 10 4 6 GP 4600 series 12 1 B 01 RS 232C 422 485 03 RS 485 isolation C T TFT color LCD W TFT color LCD Wide Type D A Analog Resisti...

Page 4: ...6 CHAPTER 2 COMPATIBILITY OF HARDWARE 8 2 1 LOCATIONS OF CONNECTOR 8 2 2 TOUCH PANEL SPECIFICATIONS 9 2 3 DISPLAY COLORS 10 2 4 PANEL CUTOUT DIMENSIONS 11 2 5 TRANSFER CABLE 11 2 6 INTERFACE 11 2 61...

Page 5: ...SOFTWARE 32 3 6 1 DIFFERENCES AFTER CONVERSION 32 CHAPTER 4 COMMUNICATION WITH DEVICE PLC 34 4 1 DRIVERS 34 4 2 SHAPES OF COM PORTS 34 4 3 SIGNALS OF COM PORTS 35 4 3 1 SIGNALS OF COM1 35 4 3 2 SIGNA...

Page 6: ...blink 16 384 colors with blink See 2 3 Display Resolution QVGA 320x240 pixels Panel Cutout Dimensions mm 191 5 W x141 5 H NEW 156 W x123 5 H See 2 4 External Dimensions mm 207 W x157 H x58 D 169 5 W x...

Page 7: ...25 pin socket RS 232C 422 D Sub 9 pin plug RS 232C See 2 6 1 and Chapter4 COM2 D Sub 9 pin plug RS 422 485 See 2 6 1 and Chapter4 Ethernet I F NEW 10BASE T 100BASE TX USB I F Type A NEW See 2 5 Type...

Page 8: ...2 Compatibility of Hardware 2 1 Locations of connector Connector locations on GP 37W2 and GP 4301TW are as follows GP 37W2 GP 4301TW Interface names GP 37W2 GP 4301TW 1 Power Input Terminal Block Pow...

Page 9: ...Touch Panel specifications GP 4301TW adopts the Analog type For the Analog type even if you touch two points at the same time it s recognized that the coordinates located between these two points are...

Page 10: ...on the screen After conversion please confirm the display colors of the drawing or the parts on the screens just in case If the display is in colors after the data conversion to GP 4301TW GP Pro EX Ve...

Page 11: ...GP 4301TW 2 5 Transfer cable To transfer screen data to GP 4301TW use a USB transfer cable or Ethernet The USB cables that can be used for GP 4301TW are as follows Model Connector Type Connector on GP...

Page 12: ...ype A or its serial interface For the models GP 4301TW supports see OtasukePro http www pro face com otasuke qa 3000 0056_connect_e html 2 7 2 Isolation Unit The isolation unit for GP 37W2 CA2 ISOALL2...

Page 13: ...Gray Light Gray Material Resin Resin with glass 2 11 Other Notes Do not expose GP4000 series to direct sunlight Do not use GP4000 series outdoors Do not turn on GP4000 series if condensation has occur...

Page 14: ...fy the data on GP Pro EX Remove GP 37W2 Installation Screen Communication Check the compatibility of hardware in Chapter 2 Check the connection between GP 4301TW and a PLC in the GP Pro EX Device PLC...

Page 15: ...ch GP Pro EX Ver 3 0 or later is installed An USB data transfer cable The following three types of cables are available An USB transfer cable model CA3 USBCB 01 An USB data transfer cable model ZC9USC...

Page 16: ...er You need to install a driver from Download on our Web site called OtasukePro http www pro face com otasuke download driver 3 3 Receive screen data from GP 37W2 This section explains as an example h...

Page 17: ...17 45 3 On the Transfer window select the Setup menu and click Transfer Settings 4 In the Communication Port field select COM specify the COM port to which the cable is connected and click OK...

Page 18: ...you use a USB transfer cable GPW CB03 You can check the COM port for the USB transfer cable GPW CB03 which is assigned to the PC with the Device Manager of Windows 5 Select the Transfer menu and click...

Page 19: ...19 45 6 Specify the location to save the received screen data at and the project file name and save them In case there is no Upload Information...

Page 20: ...n by a third party You can check in the following way if the Upload Information has been sent or not 1 Enter into the GP s Offline mode 2 If there are 2 asterisk marks in the Main menu as shown below...

Page 21: ...his part the version of the software you use is displayed 2 The Project Converter starts up and the Project Converter dialog box opens Select Project File PRW in the Data Type 3 Click the Browse butto...

Page 22: ...22 45 4 In Convert To designate a GP Pro EX s project file prx Click the Browse button and enter a new File Name e g Product system A prx Click Save and a new project file will be set to Convert To...

Page 23: ...23 45 NOTE When a convert to file exists the window that confirms whether or not to overwrite the file is displayed...

Page 24: ...24 45 5 Click Convert and start the conversion 6 If you are asked about the Convert To type as shown below select GP 4301TW on the pull down menu Click OK...

Page 25: ...rsion If an error message is displayed during conversion refer to Project Converter Error Message http www pro face com otasuke qa gp3000 replace soft conv project_con verter_error html on our Web sit...

Page 26: ...differences made at the time of conversion from GP Pro PBIII for Windows are described in the saved file the project file prx after conversion can be checked and modified according to the conversion i...

Page 27: ...can transfer data to GP 4301TW via An USB transfer cable model CA3 USBCB 01 An USB data transfer cable model ZC9USCBMB1 A commercial USB cable USB Type A mini B An USB storage device Ethernet But thi...

Page 28: ...USB driver depending on the security level of Windows XP Click Continue Anyway to start installing the driver When installation is completed click Finish If the following symptoms appear on Microsoft...

Page 29: ...on the display unit After transferring a project file once this screen will not appear again 3 On the GP Pro EX s State Toolbar click the Transfer Project icon to open the Transfer Tool To transfer a...

Page 30: ...Settings field and click OK 5 Click Send Project to start transfer When the following dialog box appears click Yes This dialog box doesn t appear when the same project file is sent again 6 The followi...

Page 31: ...ange from Transferring to Complete Transfer Click Close to close the dialog box The display unit will be reset and a screen of the transferred project file will be displayed 8 Close the Transfer Tool...

Page 32: ...tch for History Data Display of Trend Graph on the window 10 About window display on a momentary switch during momentary operation 11 About the performance when a display area of the system window is...

Page 33: ...en Data of DOS 28 Compatibility of Standard Font 29 D Script starts right after screen change or power on Compatibility of D Script Trigger Condition 30 The position shifts when loading a window scree...

Page 34: ...rs will be added For the devices PLC each driver supports see Connectable Devices http www pro face com product soft gpproex driver driver html 4 2 Shapes of COM ports GP 37W2 GP 4301TW COM1 D Sub 25...

Page 35: ...35 45 4 3 Signals of COM ports 4 3 1 Signals of COM1 For GP 37W2 RS 232C or RS 422 socket...

Page 36: ...36 45 For GP 4301TW RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown...

Page 37: ...37 45 4 3 2 Signals of COM2 For GP 37W2 None For GP 4301TW RS 422 485 plug...

Page 38: ...to 1 1 For the communication drivers that support serial multi link see Which drivers support serial multilink communication http www pro face com otasuke files manual gpproex new device com_mlnk ht m...

Page 39: ...Pro EX Device PLC Connection Manual and prepare a connection cable for GP 4301TW newly When using Mitsubishi PLC A QnA series CPU Direct please refer the following notes o When using GP430 IP10 O GP4...

Page 40: ...cable GP 37W2 System Configuration connecting to COM1 GP 4301TW System Configuration connecting to COM1 To replace GP 37W2 with GP 4301TW prepare the following item Product Name Model RS 232C 9 pin 25...

Page 41: ...Mitsubishi PLC GP430 IP10 O GP430 IP11 O with GP 37W2 be sure to select VCC in the Device PLC Setting on GP Pro EX after converting a project file or the communication will not work properly To change...

Page 42: ...MPORTANT Before connecting to GP 4301TW be sure to change the port setting to COM2 on Device PLC Setting of GP Pro EX Please check the communication setting with GP Pro EX Device PLC Connection Manual...

Page 43: ...TE When using a terminal block adapter GP070 CN10 O we recommend you to replace it with a terminal block conversion adapter PFXZCBADTM1 for GP 4301TW For replacement in this connection method prepare...

Page 44: ...lease replace to Mitsubishi A connection cable by Pro face CA3 CBLA 01 Not available options for 4000 series RS 422 9 25 pin Conversion Cable 20cm PFXZCBCBCVR41 COM Port Conversion Adapter CA3 ADPCOM...

Page 45: ...FX connection cable by Pro face CA3 CBLFX 5M 01 5m or CA3 CBLFX M 01 1m Not available options for 4000 series RS 422 9 25 pin Conversion Cable 20cm PFXZCBCBCVR41 COM Port Conversion Adapter CA3 ADPCOM...

Reviews: