background image

 

Chapter 5

 

Appendix 

5.1.

 

Changing the setting of the external media to use 

 

If a CF card is used for GP3000 series, after the display unit type of the project file 

is changed to SP5000 series, “a CF card” is automatically replaced with “a SD 
card” for the external media setting.

 

 
(1)

 

To use a USB flash drive instead of a SD card ->

Solution 1

 

(2)

 

To check 

or change the SD card’s data output destination folder setting

 

->

Solution 2

 

 
 

[Solution] 

(1)

 

Change the SD Card setting to the USB storage setting following the steps 
below. 

 
<Procedure> 

i.

 

Click [Project]->[Information]->[Destination Folder]. 

ii.

 

Uncheck “Enable SD Card” and check “Enable USB Storage.

 

 

 

 
 

iii.

 

Click the [Browse] button and specify a destination folder. 

 
 

 

 

Summary of Contents for AGP3600-T1-AF

Page 1: ...Easy Smooth Replacement Guidebook GP 3600T SP 5600TA Advanced Display SP 5B10 Power Box SP 5B00 Standard Box The 6th Edition Jun 2020 ...

Page 2: ...CANOpen type AGP3600 T1 AF CA1M SP 5600TA Advanced Display SP 5B10 Power Box CANopen Master Unit Model No PFXZCHEUCAM1 see 1 2 AGP3600 T1 D24 CA1M Display and Box of SP5000 series can be separated so you can freely select a suitable combination of them according to use This guidebook introduces specifications for a combination of SP 5600TA Advanced Display that is a 12 inch display module and SP 5...

Page 3: ...I O INTERFACE AUX 13 2 4 3 SOUND OUTPUT INTERFACE 13 2 4 4 FLEXNETWORK INTERFACE FLEXNETWORK INTERFACE CANOPEN INTERFACE DIO INTERFACE 13 2 4 5 CF CARD INTERFACE 14 2 5 PERIPHERAL UNITS AND OPTION UNITS 15 2 5 1 BARCODE 2D TWO DIMENSIONAL CODE READER CONNECTION 15 2 5 2 PRINTER CONNECTION 15 2 5 3 EXPANSION UNIT 15 2 5 4 ISOLATION UNIT 16 2 6 BACKUP BATTERY 16 2 7 SUPPORTED FEATURES 17 2 8 POWER C...

Page 4: ...0 SERIES 26 3 6 DIFFERENCES OF SOFTWARE 30 CHAPTER 4 COMMUNICATION WITH DEVICE PLC 31 4 1 SHAPES AND COMMUNICATION METHOD OF COM PORTS 31 4 2 SIGNALS OF COM PORTS 31 4 3 CABLE DIAGRAM AT THE TIME OF REPLACEMENT 32 4 4 MULTILINK CONNECTION 32 CHAPTER 5 APPENDIX 33 5 1 CHANGING THE SETTING OF THE EXTERNAL MEDIA TO USE 33 ...

Page 5: ...Panel Cut Dimensions W301 5 H227 5mm External Dimensions W313 H239 D56mm NEW W315 H241 D67mm 2 Touch Panel Type Resistive film Analog UP Resistive film Analog Single touch Memory Application 16MB UP 64MB SRAM SRAM 320KB UP NVRAM 320KB Backup Battery Secondary Battery Rechargeable Lithium battery UP see 2 6 Input Voltage DC24V AC 100 to 240V NEW DC 12 to 24V see 2 2 Serial I F COM1 D Sub9 pin plug ...

Page 6: ... piece terminal block AUX x 1 3 FLEXNETWORK I F AGP3600 T1 AF FN1M AGP3600 T1 D24 FN1M 3 CANopen I F AGP3600 T1 AF CA1M 3 DIO I F AGP3600 T1 AF D81 AGP3600 T1 D24 D81 only 3 Expansion Unit I F Communication Unit 3 Expansion Unit I F Image Unit Expansion Memory 4 Software GP Pro EX 2 00 or later GP Pro EX 4 08 200 or later 1 SP 5B00 does not support hardware 3rd speed blink 2 Size for the time when...

Page 7: ...7 34 4 No expansion memory but SP5000 series has enough memory to cover GP3000 series expansion memory ...

Page 8: ... 2 9 Panel Cut Dimensions W301 5 H227 5mm External Dimensions W313 H239 D56mm NEW W315 H241 D67mm 1 Touch Panel Type Resistive film Analog UP Resistive film Analog Single touch Memory Application 16MB UP 64MB SRAM SRAM 320KB UP NVRAM 320KB Backup Battery Secondary Battery Rechargeable Lithium battery UP see 2 6 Input Voltage DC24V AC 100 to 240V NEW DC 12 to 24V see 2 2 Serial I F COM1 D Sub9 pin ...

Page 9: ... Speaker Output 300mW or more Rated Load 8Ω Frequency 1kHz LINE Output 1 4Vp p Rated Load 10kΩ Connector 2 piece terminal block AUX x 1 See 2 4 3 FLEXNETWORK I F AGP3600 T1 AF FN1M AGP3600 T1 D24 FN1M FLEXNETWORK Unit Model No PFXZCHEUFN1 is required For more details refer to FAQ FA330215 CANopen I F AGP3600 T1 AF CA1M CANopen Master Unit Model No PFXZCHEUCAM1 is required For more details refer to...

Page 10: ...ww proface com en support faq page content country PROFACE lang en locale en_US id FA315627 prd redirect true FLEXNETWORK Unit Model No PFXZCHEUFN1 https www proface com en support faq page content country PROFACE lang en locale en_US id FA330215 prd redirect true CANopen Master Unit Model No PFXZCHEUCAM1 https www proface com en support faq page content country PROFACE lang en locale en_US id FA3...

Page 11: ... 34 Chapter 2 Compatibility of Hardware 2 1 Locations of connector Connector locations of GP 3600T and SP 5600TA SP 5B10 SP 5B00 GP 3600T SP 5600TA Advanced display SP 5B10 Power box SP 5B00 Standard box ...

Page 12: ...put I F AUX 11 Expansion Unit I F Image Unit 12 Expansion Memory Cover 2 2 Power supply SP5000 has a DC power supply type only When replacing GP 3600T AC type with SP5000 series changing to DC power supply is required For the detailed electric specifications see the hardware manual 2 3 USB Transfer cable Like the GP3000 series a USB transfer cable CA3 USBCB 01 can be used for the SP5000 series Als...

Page 13: ...ro EX Note that RUN Output and External Reset Output that used to be used for GP 3600T cannot be used anymore 2 4 3 Sound Output Interface If sound output is needed select SP 5B10 Power Box and use AUX I F When using Speaker Output the output value has increased from 70mW to 300mW so customers using an amplifier should be aware of it 2 4 4 FLEXNETWORK interface FLEXNETWORK interface CANopen interf...

Page 14: ...tem and the other for backup Use the interface of the SD card for backup When using a SD card with SP 5B10 Power box please verify it supports the following specifications File format Maximum capacity SD FAT16 2GB SDHC FAT32 32GB When the setting of the output destination folder is set to CF Card on GP Pro EX if you change the display unit type the setting will automatically change to the one that...

Page 15: ... 3 Expansion Unit If you used GP3000 series VM unit RGB input unit please refer to the Replacement Guidebook for GP4621T If you used PROFIBUS unit for GP3000 series SP 5B10 Power Box is required for the replacement If you used PROFIBUS unit for GP3000 series model CA5 PFSALL EX 01 please apply PROFIBUS DP Slave model no PFXZCDEUPF1 for SP 5B10 Power box Reference FA315627 Replacement for GP3000 se...

Page 16: ... Pro EX RS 422 485 2 wire type communication and serial multilink are not supported 2 6 Backup Battery SP 5B10 SP 5B00 Standard box is not needed a backup battery for Clock Supercapacitor electric double layer capacitor can be back up clock data Please note the following points When the voltage from the Supercapacitor is low clock data is lost when this product is turned OFF In order to charge up ...

Page 17: ... wish to use lower resolution SVGA 800 600 as it was please select SP 5600TP Premium Display for the Display unit If you check on Convert Resolution when changing the Display Unit type as shown below you can adjust both size and location of the part and the text relative to the display resolution automatically But please note that their width gets larger due to change of horizontal resolution of t...

Page 18: ...ng SP 5B00 Standard BOX use Pro Server EX Ver 1 36 or later 2 11 Other Notes Do not expose SP5000 series to direct sunlight Do not use SP5000 series outdoors Do not turn on SP5000 series if condensation has occurred inside the device When you are continuously using SP5000 series without oxygen the brightness might decrease Please ventilate the control panel periodically ...

Page 19: ...eration Change the received data on GP Pro EX Check and modify the data on GP Pro EX Transfer the screen data to SP5000 series Check the connection between SP5000 series and a PLC in the GP Pro EX Device PLC Connection Manual Connect SP5000 series and PLC with the PLC s cable Start connection and check the communi cation 1 This step is required if screen data is saved only in the GP unit not in an...

Page 20: ...MB1 A commercial USB cable USB Type A mini B Possible to send receive a screen via a SD card a USB storage device or Ethernet 1 This step is required if screen data is saved only in the GP unit not in any other device 2 Please use the same version or later as or than that of the software used during creating screens on GP3000 Series If you don t know the version we recommend you to use the newest ...

Page 21: ...3 4 Change the Display Unit Type 1 Connect your PC and GP3000 Series with a USB transfer cable If the driver of the cable has not been installed on your PC yet a dialog box will appear Please follow the instructions NOTE The Hardware Installation dialog box as shown below may appear during installing the USB driver depending on the security level of Windows Click Continue Anyway to start installin...

Page 22: ... GP Pro EX 3 Make sure that the Device in the Transfer Settings Information is set to USB If not click the Transfer Setting button to open the Transfer Setting dialog box Select USB in the Communication Port Settings field and click OK ...

Page 23: ...on 5 Click Receive Project and the following dialog box will appear Specify a place to save the received data in and a project file name and then click Save to start transfer NOTE When a file exists the window that confirms whether or not to overwrite the file is displayed ...

Page 24: ...ollowing dialog box will appear during transfer Specify a place to save the CF card data in Click OK and the Receive Project dialog box will return and transfer will be completed 2 SP5000 series that is a replacement model is not equipped with a CF card slot If the display unit type is changed to SP5000 series the CF card setting will be replaced with the SD card setting automatically To check or ...

Page 25: ...25 34 7 When transfer is completed the status displayed in the dialog box will change from Transferring to Complete Transfer Click Close to close the dialog box 8 Close the Transfer Tool ...

Page 26: ...placement model 3 Click Project Save As and save the changed project file 3 5 Transfer the screen data to SP5000 series Transfer the project file after the display unit type change to SP5000 series You can transfer data to SP5000 series via An USB transfer cable model CA3 USBCB 01 An USB data transfer cable model ZC9USCBMB1 A commercial USB cable USB Type A mini B A SD card USB storage device Ethe...

Page 27: ...he Hardware Installation dialog box as shown below may appear during installing the USB driver depending on the security level of Windows Click Continue Anyway to start installing the driver When installation is completed click Finish 2 Turn on the power of SP5000 series The Initial Start Mode screen will appear on the display unit After transferring a project file once this screen will not appear...

Page 28: ...er a different project file click the Select Project button and select a project file 4 Make sure that the Device in the Transfer Settings Information is set to USB If not click the Transfer Setting button to open the Transfer Setting dialog box Select USB in the Communication Port Settings field and click OK ...

Page 29: ...r and you can check the communication status The display unit enters the Transferring mode and communication with the device such as a PLC is terminated 7 When transfer is completed the status displayed in the dialog box will change from Transferring to Complete Transfer Click Close to close the dialog box The display unit will be reset and a screen of the transferred project file will be displaye...

Page 30: ...Pro EX 3 6 Differences of software Some functions supported by GP3000 Series are not supported by SP5000 series For details of the details of the supported parts and functions refer to Supported Features of GP Pro EX Reference Manual http www pro face com otasuke files manual gpproex new refer gpproex ht m ...

Page 31: ...between the COM2 port on GP 3600T and the COM2 port on SP 5B10 Power box SP 5B00 Standard box Pin Arrangement Pin No GP 3600T SP 5B10 Power box SP 5B00 Standard box Signal Name Direction Meaning Signal Name Direction Meaning 1 TRMRX Termination Receive side 100Ω RDA Input Receive Data A 2 RDA Input Receive Data A RDB Input Receive Data B 3 SDA Output Send Data A SDA Output Send Data A 4 RS RTS Out...

Page 32: ...GP 3600T s COM2 cable For the following case only it can be used for the COM1 COM2 on SP 5B10 Power box COM2 on SP 5B00 Standard box if the COM Port Conversion Adapter CA3 ADPCOM 01 is added to the GP s side When an online adapter CA4 ADPONL 01 is attached to the GP 3600T s cable detach it RS 422 cable CA3 CBL422 01 2 port adapter cable CA3 MDCB11 2 port adapter II GP070 MD11 Multi link cable CA3 ...

Page 33: ... for the external media setting 1 To use a USB flash drive instead of a SD card Solution 1 2 To check or change the SD card s data output destination folder setting Solution 2 Solution 1 Change the SD Card setting to the USB storage setting following the steps below Procedure i Click Project Information Destination Folder ii Uncheck Enable SD Card and check Enable USB Storage iii Click the Browse ...

Page 34: ...th the one of USB Storage NOTE To check each function setting of GP Pro EX refer to GP Pro EX Reference Manual 2 Check and change the destination folder setting following the steps below i Click Project Information Destination Folder ii The current setting is displayed iii After changing it click OK to confirm the setting iv Click Project Save to save changes ...

Reviews: