Wiring the Floodlight
•
Ensure that the mains supply is isolated before commencing installation.
•
A suitable rated connector must be used to connect the lead from the floodlight to
the mains supply.
•
Connect the mains cable to the connector. Ensure that the correct polarities for
Live, Neutral and Earth are observed i.e.
- Green/yellow - Earth terminal
- Brown - Live terminal
- Blue - Neutral terminal
After wiring, check that there are no stray strands and that all the wires have been
correctly installed.
•
Before connecting power, perform the electrical tests specified in the current
Building and IET Wiring Regulation to ensure that the installation is safe and that
the wiring has been performed correctly.
•
Restore the mains power supply and check that the floodlight illuminates the
required area. Tighten the floodlight using the bolts on the brackets.
CLEANING & MAINTENANCE
•
Clean the floodlight only with a soft dry cloth. Do not use any chemicals, abrasives
or solvents that could damage the floodlight.
•
The floodlight has a sealed LED lamp and is maintenance free. The LED lamp
cannot be replaced. When the LED lamp reaches the end of its life, the floodlight
will have to be replaced.
SPECIFICATION
Model
PELL0268
PELL0269
PELL0270
PELL0271
PELL0272
Cable length
1m
1m
1m
1m
1m
Input Voltage
220-240V
AC 50Hz
220-240V AC
50Hz
220-240V
AC 50Hz
220-240V
AC 50Hz
220-240V
AC 50Hz
Luminous flux
800lm
1600lm
2400lm
4000lm
8000lm
Wattage
10W
20W
30W
50W
100W
Beam angle
120°
120°
120°
120°
120°
Dimmable
No
No
No
No
No
Nominal lifetime
25,000h
25,000h
25,000h
25,000h
25,000h
Light source
SMD2835
SMD2835
SMD2835
SMD2835
SMD2835
Colour
temperature
6000-6500K
6000-6500K
6000-6500K 6000-6500K 6000-6500K
Ingress rating
IP65
IP65
IP65
IP65
IP65
Earthing
Class I
Class I
Class I
Class I
Class I
Weight
0.27kg
0.37kg
0.57kg
0.74kg
1.28kg
Dimensions
WxHxD (mm)
133x95x37
160x115x40
208x147x40 235x173x44 316x225x52