8
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF
ELECTRICAL & ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste Electrical
& Electronic Equipment (WEEE). Any WEEE marked products must not be mixed with
general household waste, but kept separate for the treatment, recovery and recycling
of the materials used. Waste batteries can be returned to any waste battery recycling
point which are provided by most battery retailers. Contact your local authority for
details of battery and recycling schemes in your area.
Made in China. PR2 9PP
Man Rev 1.0
Cd
SPECIFICATIONS
Input voltage:
220-240V~, 50Hz
Rated power:
16W
Lamps:
SMD2835 LEDs x 60pcs
Luminous flux:
980Lm(AC) / 200Lm(DC)
Continuous emergency illumination:
> 3 hours (when the battery is fully charged)
Battery pack:
Ni-Cd, 6V, 2Ah
Recharge time:
24 hours – approx.
Ambient temperature:
0 - 40°C
Over-discharge protection:
Yes
Ingress protection rating:
IP65
Changing a fuse
•
Two fuses are fitted to this product and are located on the mains connection
terminal block and can be changed as follows:
1. Isolate from the mains supply.
2. Remove the diffuser and release the main LED plate assembly.
3. Pull the fuse holder out of the terminal block
4. Press the fuse out of the holder and replace with an identical fuse (240V F3A).
5. Insert the fuse holder back into the terminal block.
6. Refit the LED plate assembly. Tighten the screws and refit the diffuser.
7. Restore the mains power and check the operation.
Changing the battery
•
If after a routine operation check, the lamp does not remain lit for the 3 hour period,
a new battery pack may be required. Change the battery pack as follows:
1. Isolate from the mains supply.
2. Remove the diffuser and release the main LED plate assembly.
3. Unplug the battery pack in line connector.
4. Loosen the battery locating nuts and remove the old battery pack.
5. Write the current date on the new battery pack.
6. Fit the new battery pack and secure in position.
7. Reconnect the battery pack in-line connector.
8. Refit the LED plate assembly. Tighten the screws and refit the diffuser.
9. Restore mains power and allow to charge for 24 hours.
10. Perform the full operation check and update the test record.