TECHNICAL DETAILS

Model No:

HG00921

Main Voltage:

220-240V ~50Hz

Rated input power:

950W

Power Standby mode:

1.0W

Cooling capacity:

2.64 kW (9000BTU/h)

Dehumidify capacity:

24L/24hr

Air flow:

380m

3

/h

Sound power level:

≤64 dB(A)

Refrigerant/Charge:

R410A/370g

Global warming potential:

1975 kgCO2 eq.

Energy Efficiency Ratio (EER):

2.64

Energy efficiency class:

A

Fans speeds:

2

Thermostat:

16 - 31°C

Recommended room floor area:

10-14m

2

Dimensions (W x H x D):

320 x 730 x 370 mm

Weight:

24kg

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL &
ELECTRONIC EQUIPMENT.

When this product has reached the end of its life it must be treated as Waste
Electrical & Electronics Equipment (WEEE). Any WEEE marked products must
not be mixed with general household waste, but kept separate for the treatment,
recovery and recycling of the materials used. Contact your local authority for
details of recycling schemes in your area.

For any enquiries regarding the product, please call 08447 88 00 88

Summary of Contents for HG00921

Page 1: ...INSTRUCTION MANUAL HG00921 Portable Air Conditioner...

Page 2: ......

Page 3: ...2 Contents CAUTION 3 INTRODUCTION 4 POSITIONING AND INSTALATION 5 6 CONTROL PANEL 7 REMOTE CONTROL 8 WATER DRAINAGE 9 MAINTENANCE 9 TROUBLESHOOTING 10 TECHNICAL DETAILS 11...

Page 4: ...zard This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given sup...

Page 5: ...ents to read the instructions thoroughly and familiarise yourself with the operation of the dehumidifier Please retain for future reference Parts Front 1 Handle 2 Control panel 3 Screen 4 Air outlet 5...

Page 6: ...ces to ensure adequate air circulation fig 1 Fig 1 4 Ensure that the mains socket outlet remains accessible when the air conditioner is in use 5 Ensure that there is free access to the air inlet and a...

Page 7: ...e 5 Close the window onto the window guide so that it is securely held in place Installation Errors To operate efficiently the air must be able to flow freely in the exhaust hose To assist this 1 Avoi...

Page 8: ...ure Temperature range is 16 C to 31o C 5 UP in cooling mode press this key to increase the temperature Temperature range is 16 C to 31o C 6 SLEEP in the cooling mode press this key to turn on off the...

Page 9: ...ndicator turns on Press FAN to select high speed or low speed When in the fan mode temperature and sleeping functions cannot be set Timer mode In standby mode press TIMER to set the number of hours to...

Page 10: ...will need to be emptied before normal operation can be resumed 1 Unplug the air conditioner from the mains supply 2 Under the drainage plug on the rear of the unit place a shallow container to collect...

Page 11: ...its original carton and store in a cool dry place TROUBLESHOOTING Below are some possible problems with their solutions Trouble Cause Solution Machine does not work Power off Power on Water full indi...

Page 12: ...efficiency class A Fans speeds 2 Thermostat 16 31 C Recommended room floor area 10 14m2 Dimensions W x H x D 320 x 730 x 370 mm Weight 24kg INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL EL...

Reviews: