The green LED is illuminated whenever the charge cycle is complete and the internal circuitry has determined the batteries to 

be fully charged. After the completion of the charge cycle, the green LED will remain on.  

  

 

     

Your system provides an auto reset stage every 30 days if left plugged in to AC.  In addition, for Li Only setting, unit 

will reset every 48 hours in to replace any battery capacity lost due to internal cell balancing.  Note:  During this 
process the LEDs will go through their normal routine (Red LEDs counting up for % of charge along with the 
illuminated  Amber LED Battery Type) until the unit returns to the maintenance mode and a steady Green LED and 
steady Amber Battery Type LED.  

     

 

     

TROUBLESHOOTING       

 

     

PROBLEM: No LED indicators illuminated on battery status indicator. 

     

 

     

Solution Sequence: 

     

1. Confirm that current is being delivered to the charger. Use a meter or test light to check the AC power supply from its 

source through all connecting points up to the charger. 

     

2. Check that the AC circuit breaker (on front of the unit) is depressed. 

     

3. Call technical support for further assistance (

615.471.5300

). 

     

 

     

PROBLEM: The charge status indicator changes rapidly back and forth from red to green or the green LED will not 

illuminate after excessive charging time (24 hours or more). 

     

 

     

Solution Sequence: 

     

1. Disconnect AC power from the charging system. This indication may signify a possible battery problem. 

     

2. Call technical support for further assistance (

615.471.5300

). 

     

PROBLEM: A green LED was illuminated before disconnecting the power from the charger, but upon reconnection, 

red LEDs appear and remain on.

 

     

 

     

LIGHT EMITTING DIODES (LED) FAULT CODE INDICATIONS       

The microprocessor is constantly monitoring the charger circuitry and will both detect and display blinking LED indications if a 

fault is detected.  The battery type LED will be 

OFF

 during a fault code condition.   

     

 

     

When first connected to DC (AC not connected), the LEDs will display one or more of the following: 

     

1. 

The LEDs will flash the charger’s ID code (this is for PCS internal use only). Once the LEDs flash the ID, they will only display one 
yellow LED. This configuration will remain until AC is detected and a charge cycle is in progress.  

     

2. 

There is also a possibility the LEDs will not flash their ID code and only show a yellow LED.  

     

3. 

Lastly, the LEDs may not flash their ID code and may not show any LEDs until AC is detected. 

     

 

     

If the AC line and neutral wires are reversed, the unit will wait 2 minutes before starting a charge. NOTE: The 2 minute wait period will also be a 

factor if the charger is being powered by anything other than normal grid AC such as a conventional generator, inverter, etc. 

   

 

     

If AC is disconnected while charging, the unit will turn off as expected. The user may hear some clicking noise, but should not be alarmed. This is 

the Powered by Battery/DOE functionality checking for AC connection. 

     

 

     

30 & 60% RED LEDS BLINKING ………………..…..…FORMING STAGE TIMEOUT SHUTDOWN  

     

This indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first 3 hours of charging.  This indicates that a possible battery 

problem exists and that the charge cycle has been terminated at this point.   

     

 

     

30, 60 & 90% RED LEDS BLINKING............................................OVERALL TIMER SHUTDOWN  

     

This indication occurs if the charger has not completed the charge cycle within the allowable factory set time period.  This indicates that a possible battery 

problem exists and that the charge cycle has been terminated at this point. 

     

 

     

30 & 90% RED LEDS BLINKING …..…..............................INTERNAL OVERTEMP SHUTDOWN  

     

This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are above factory specified levels.  This 

could indicate that a possible charger problem exists and that the charge cycle has been terminated.   

     

Summary of Contents for 2425LITH

Page 1: ...H 4818LITH 4818OBLITH 7212LITH 070820 70353 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC power to your Pro Charging Syste...

Page 2: ...TANTES CONCERNANT LA S CURIT SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for future reference CONCERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES INSTRUCTION...

Page 3: ...smoke or allow a spark or flame in the vicinity of battery or engine Don t expose to rain Keep work area well lit 8 Do not overreach Keep proper footing and balance at all times Do not reach over or...

Page 4: ...osive gases during normal battery operation For this reason it is of utmost importance that prior to each use of your charger you read this manual and follow the instructions exactly Il est dangereux...

Page 5: ...or short circuit a battery or other electrical part possibly resulting in an explosion If damaged contact PCS 615 471 5300 NEVER charge a frozen battery Ne jamais charger une batterie gel e Assure tha...

Page 6: ...ormal operation For this reason it is of the utmost importance that prior to each use of your charger you read and follow the instructions provided exactly Il est dangereux de travailler a proximit d...

Page 7: ...a fault is detected The battery type LED will be OFF during a fault code condition When first connected to DC AC not connected the LEDs will display one or more of the following 1 The LEDs will flash...

Page 8: ...warranty If such defects should occur this unit will either be repaired or replaced at the discretion of the manufacturer It is the responsibility of the original purchaser to return the charger alon...

Page 9: ...9...

Reviews: