3.0   SYSTEM COMPONENTS 
        

DEVICE COMPONENTS AND MARKINGS

1.  Micro-Z Mini™ Device 

A. Intensity Control Increase 

2.  Two (2) lead wires 

B. Intensity Control Decrease

   

 One (1) red 

C. On/Active Switch

  

 One (1) black 

D. Micro-Z Mini™

3.  One (1) AAA Battery 

E. LCD Display

4.  Velcro Arm / Leg Strap

5.  Conduct Mist™ or TheraCream™

1

2

3

4

5

Summary of Contents for Micro-Z MINI

Page 1: ...ease read all instructions carefully before use CAUTION Federal law USA restricts this device to sale by or on the order of a physician Rev 8 2007 P N 0 61 MZMMAN 0 1 Manufactured for P O Box 40 Oakwo...

Page 2: ...Device 4 2 Electrode Placement 4 3 Powering the Device 4 4 Connecting the Lead Wires 4 5 Turning the Device On 4 6 Protocol Selection 4 7 Treatment Intensity 4 8 Powering the Device Off 5 0 SETTING CL...

Page 3: ...a full variety of frequencies time settings and delivery schedules Designed for use with our patented garment electrodes wearable electrodes that cover a large surface area providing total stimulatio...

Page 4: ...ices during pregnancy TENS is not effective for pain of the central origin This includes headache TENS devices should be used only under the continued supervision of a physician or qualified professio...

Page 5: ...veness is highly dependent upon patient selection by a person qualified in the management of pain PRECAUTIONS Continued 2 4 2 NMES 1 Precautions should be taken in the presence of A tendency to hemorr...

Page 6: ...S 1 Micro Z Mini Device A Intensity Control Increase 2 Two 2 lead wires B Intensity Control Decrease One 1 red C On Active Switch One 1 black D Micro Z Mini 3 One 1 AAA Battery E LCD Display 4 Velcro...

Page 7: ...ith the above cautions in mind Follow all instructions for the electrode use 4 3 Powering the Device The Micro Z Mini is powered by one 1 AAA battery Remove the battery compartment cover from the back...

Page 8: ...the Increase button to set the protocol and intensity level The P will stop flashing and as you continue to press the button the intensity will increase and the LCD will display the numeric value The...

Page 9: ...l run the display will show time remaining in hours and minutes or minutes and seconds During the Dwell time of protocol 2 P2 the intensity setting will flash 5 2 Clinician Value Details The Micro Z M...

Page 10: ...not enough voltage to sustain therapy 7 0 CARE AND CLEANING Do not store the Micro Z Mini with the battery installed Battery acid causes irreparable damage which is not covered by the warranty When n...

Page 11: ...defective parts provided the device has been properly packaged and returned postage prepaid to the manufacturer This warranty is rendered void if damage to the device results from mishandling misuse a...