TECHNICAL DESCRIPTION
The fireboxes with built in heat exchanger and turbine fan are designed to heating
the room in which they are installed and air heating of remote premises.
They are made of low carbon sheet steel and include: combustion chamber,
stainless steel heat exchanger, cast iron door of the combustion chamber with glass
ceramic, cast iron grate,
cast iron comb, refractory bricks, flue gas outlet with a valve,
ash drawer with a valve for regulating the primary air.
№
Model
Dimensions
W / D / H
,cm
Max. Power, kW Weight,
kg
Flue gas outlet
diameter, m
m
1
Firebox PRITY CF
66 / 61 / 117
18
150
200
2
Firebox PRITY 2CF
73 / 73 / 113
18
188
200
3
Firebox PRITY ТCF
108 / 60 / 114
18
190
200
4
Firebox PRITY ТC2F
108 / 60 / 131
20
215
200
Achieving the desired power depends on the selected fuel with the required calorific
value and humidity; their consistent ignition and addition; regulation of the primary,
the secondary air and the draught; organization of efficient air heat exchange etc.
INSTALLATION INSTRUCTIONS
When installing the firebox, all local legal regulations, including those, relating to
the national or European standards, must be observed.
The firebox is placed on a stable horizontal non
-
combustible floor with sufficient
load capacity. It is lined with construction materials which shape its design. In front of
the door there must
be a stable non
-
flammable pad that protrudes at least 50 cm.
In the area of radiation there must be no objects flammable and damageable by the
radiated heat.
Before connecting the fireplace to the chimney, consult a specialist, who shall give
you a written guarantee for its functional safety.
The connecting elements (rosette and chimney) must be installed tightly and
permanently, but so that they may not enter the passage section of the chimney. The
pipes must have the same size as the extension of the firebox.
It is recommended that the firebox work with a separate chimney. If other heating
appliances are connected in the same chimney, it must be designed (calculated) for
that.
The firebox must receive fresh air at least 4m
3
/h for each kilowatt of its heat
power.
If necessary, an inflow from adjacent premises or air outside must be provided.
Summary of Contents for 2CF
Page 2: ...2...
Page 4: ...4 4m3 h 220V 50Hz 101W S1 1 2...
Page 5: ...5 A B C...
Page 6: ...6 2 12 I 20 2 5 15cm 1 20kg 10kg 10 2 3 II...
Page 7: ...7 1 2 3 4 5 6 7 III 0 36 0 5kg...
Page 8: ...8 IV 1 2 3 4 5 V 5 10 VI...
Page 9: ...9...
Page 10: ...10 EN 13229 2006 24 36 I 112 115 112 1 2 1 2 3 113 1...
Page 11: ...11 2 3 2 114 4 5 114 1 113 1 2 2 3 115 4 115 1 2 1 3 1 1 II 112 115 112 115 III...
Page 12: ...12 95 33 0898 258 801 www prity bg com...
Page 23: ...23...
Page 24: ...PRODUCT MODEL Date of manufacture Serial number QC passed Stamp...