5
CONNECTION
Push Button
1
Push
Button 2
NFC/RFID
LED
light ring
LED
in front
USB
AC/DC
Direct
constant
supply*
PowerAmp
Internal LS
Vibrator
driver
PowerAmp
External LS
Opto
Opto
Opto
Opto
4
21
22
4
23
11
K1
K2
+
-
10
30
20
6
5
Opto
31
32
40
41
42
51
50
External Loudspeaker
[Option]
Output K2 (NC)
Output K2 (NO)
Input K2 (IN)
Output K1 (NC)
Output K1 (NO)
Input K1 (IN)
Common 0V ref.point direct constant supply*
Common ref. point for opto inputs
Common ref. point for red and green
Green pedestrian light
Red pedestrian light
Night option signal
Wire 1 in programming equipment
Extra option signal
Wire 3 in programming equipment
Wait signal (or option)
Wire 2 in programming equipment
Direct constant supply*
Normally used as
RFID/special signal
Normally used as
demand signal
NOTE
• 13-wires is recommended as a standard cabling for new intersections.
• With 28-49V AC/DC, and 18-24V AC/DC, 13-wires can be used if the common reference point for red and green lights can be connected
to the common reference point for Direct Constant Supply.
• Adapter cabling is used when exchange of the electronic module from Prisma Daps 1000 or Prisma Daps TS-900-series to Prisma Daps 2000.
• A customized cabling can be provided on request.
Depending on the number of wires in your cabling, functions can possibly be limited.
Example of functions that might not be usable are relay 2, wire 3 and external loudspeaker.
* Separate direct constant supply - not through the lamp cable
ERROR HANDLING
Visit: www.prismatibro.se/en/error-da
Or: Scan QR-code