background image

5

CONNECTION

Push Button 

1

Push

Button 2

NFC/RFID

LED

light ring

LED 

in front

USB

AC/DC

Direct

constant 

supply*

PowerAmp

Internal LS

Vibrator

driver

PowerAmp

External LS

Opto

Opto

Opto

Opto

4

21

22

4

23

11

K1

K2

+

-

10

30

20

6
5

Opto

31

32

40
41

42

51
50

External Loudspeaker

[Option]

Output K2 (NC)

Output K2 (NO)

Input K2 (IN)

Output K1 (NC)

Output K1 (NO)

Input K1 (IN)

Common 0V ref.point direct constant supply*

Common ref. point for opto inputs

Common ref. point for red and green

Green pedestrian light

Red pedestrian light

Night option signal

Wire 1 in programming equipment

Extra option signal

Wire 3 in programming equipment

Wait signal (or option)

Wire 2 in programming equipment

Direct constant supply*

Normally used as

RFID/special signal

Normally used as

demand signal

NOTE

•  13-wires is recommended as a standard cabling for new intersections.

•  With 28-49V AC/DC, and 18-24V AC/DC, 13-wires can be used if the common reference point for red and green lights can be connected

  to the common reference point for Direct Constant Supply.

•  Adapter cabling is used when exchange of the electronic module from Prisma Daps 1000 or Prisma Daps TS-900-series to Prisma Daps 2000.

•  A customized cabling can be provided on request.

Depending on the number of wires in your cabling, functions can possibly be limited.

Example of functions that might not be usable are relay 2, wire 3 and external loudspeaker.

* Separate direct constant supply - not through the lamp cable

ERROR HANDLING

Visit: www.prismatibro.se/en/error-da

Or: Scan QR-code

Summary of Contents for Prisma Daps 2000

Page 1: ...1 DIGITAL ACOUSTIC PEDESTRIAN SIGNAL INSTALLATION MANUAL 2000...

Page 2: ...actile direction arrow Top cover LED light ring Service hook Cable Terminal Electronic module LED in front Front Relief symbols mounting example Housing Decorative profile LED protection lens Bottom l...

Page 3: ...and drill the holes Z OPTION 2 When it is impossible to install the screws from the rear 1 Remove the top cover B and the LED light ring C turn out the service hook D and place the cover on the servi...

Page 4: ...CABLE IS NOT USED SINCE THE Prisma Daps 2000 IS DOUBLE INSULATED 21 4 5 6 To connect the 13 wire cabling to a 7 wire connector see picture below Pink violet beige and transparent are not used Keep th...

Page 5: ...ramming equipment Direct constant supply Normally used as RFID special signal Normally used as demand signal NOTE 13 wires is recommended as a standard cabling for new intersections With 28 49V AC DC...

Page 6: ...intersection and the direction of the crossing Therefore it s crucial that they are turned and positioned absolutely correctly The START symbol nr 1 should always be at the bottom and then the differ...

Page 7: ...ma Daps 2000 Customized cabling on request Colour Blue anodization Gold anodization Yellow varnished Gray varnished Black vanished Other colours on request Anti graffiti Possible to add on all colours...

Page 8: ...of God We support different projects that helps children by building new schools providing clean water and diverting them from a life in crime There is so much we can do to help and we are committed t...

Reviews: