7
ELECTRICAL CONNECTION
Check that the power supply voltage, the frequency and the power of the system are compatible with the
values indicated both in the technical features and on the plate affixed to the back of the oven.The
characteristics of the power supply socket must be compatible with the plug installed on the cable.
THE ELECTRICAL CONNECTION OF THE OVEN TO THE POWER SUPPLY NETWORK
MUST ONLY BE PERFORMED BY AN AUTHORISED TECHNICIAN (ELECTRICIAN) IN
POSSESSION OF THE TECHNICAL-PROFESSIONAL REQUIREMENTS IMPOSED BY
THE APPLICABLE RULES IN THE COUNTRY OF USE OF THE OVEN. REQUEST
ISSUING OF A DECLARATION OF CONFORMITY OF THE INTERVENTION
PERFORMED.
FOR DIRECT CONNECTION TO THE NETWORK, IT IS NECESSARY TO USE A DEVICE
WITH AN OPENING BETWEEN THE CONTACTS THAT ENSURES COMPLETE
DISCONNECTION IN THE CONDITIONS OF THE OVERVOLTAGE CATEGORY III, IN
ACCORDANCE WITH THE INSTALLATION RULES.
To connect the machine to the electrical network, proceed as follows:
fit a normalised and polarised plug at the other end of the cable (the distinction between phase and
neutral must be unequivocal).
WITH ELECTRICAL CONNECTION COMPLETED, THE AUTHORISED TECHNICIAN
(ELECTRICIAN) MUST ISSUE A DECLARATION THAT CERTIFIES THE CONTINUITY
MEASUREMENT OF THE EQUIPOTENTIAL PROTECTION CIRCUIT.
THE APPLIANCE IS TO BE SUPPLIED THROUGH A RESIBASIC CURRENT DEVICE
(RCD) HAVING A RATED RESIBASIC OPERATING CURRENT NOT EXCEEDING 30 MA.
Summary of Contents for C/0
Page 1: ...ENGLISH INSTALLATION OPERATION AND MAINTENANCE MANUAL VENTILATED AIR TUNNEL OVEN C 0...
Page 2: ...1...
Page 23: ...22 SPARE PARTS EXPLOSION OVEN...
Page 24: ...23 EXPLOSION DOOR...
Page 25: ...24 EXPLOSION SYSTEM...
Page 27: ...26 ELECTRICAL PART WIRING DIAGRAM C 40 AND C 50...
Page 28: ...27 WIRING DIAGRAM C 65 AND C 80...
Page 29: ...28...