background image

16

Dilution chart

Product used 

as:

Device 
condition

Concentration 
(ppm)

Dilution 
qty *

Tablets 
per litre

Contact 
time

Bactericidal

Clean

200

5 litre

1

1 minute

Dirty

1000

1 litre

1

5 minutes

Yeasticidal

Clean

200

5 litre

1

1 minute

Dirty

1000

1 litre

1

5 minutes

Fungicidal

Clean

2000

1 litre

2

15 minutes

Dirty

5000

1 litre

5

15 minutes

Mycrobactericidal

Clean

1000

1 litre

1

15 minutes

Dirty

5000

1 litre

5

15 minutes

Virucidal

Clean

500

2 litre

1

5 minutes

Dirty

1000

1 litre

1

5 minutes

Sporcidal (C.Diff)

Clean 

1000

1 litre

1

10 minutes

-

-

-

Sporcidal 

Clean

5000

1 litre

5

10 minutes

-

-

-

* Dilution is made within water
•  When diluted in water, one tablet gives 1000 ppm of available chlorine DO NOT dilute within any other 

medium

•  The concentration of the solution depends upon whether the device being cleaned is noticeably dirty or 

note (indicated in the table by “Device Condition” 

Summary of Contents for Easy Fit

Page 1: ...1 User Manual...

Page 2: ...of the Easy Fit System Page 6 3 Features and Specifications Page 7 4 Assembly Instructions Page 8 10 5 Placement of Easy Fit System Page 11 6 Troubleshooting Page 12 13 7 Pre use inspection and Mainte...

Page 3: ...ully read this entire manual especially the section on Cautions Failure to comply with warnings in this manual may result in injury to the operator or the individual being lifted transferred Damage to...

Page 4: ...roviding care in the home to lift position and transfer clients or a disabled family member The Easy Fit System is part of what is termed overhead lift technology which takes advantage of lifting from...

Page 5: ...where more than one operator will be responsible for using the Easy Fit System associated lift and sling s it is imperative that all operators be trained in its proper use Never expose the Easy Fit d...

Page 6: ...6 Easy Fit Components Description Quantity Bottom Plate 2 Top Plate 2 Support Post 2 Adjustable Track 1 Post Pins 2 Pin R Clips for post pins 2 Owner s manual 1 Component List 2 Components...

Page 7: ...easy slide trolley Exerting pressure between Floor and Ceiling is 80 to 100 lbs Specially designed and engineered rubber moulded feet for ultimate grip Levelling indicators on posts One 1 year warran...

Page 8: ...nything look unusual contact your authorised dealer prior to use Failure to comply with this caution could result in serious injury to the operator the individual being lifted and or damage to the Eas...

Page 9: ...ock and check that the bubble is within the central circle by adjusting the position of the Support Post 8 Pull the lever down until it flat to the support leg and clicks into place 9 Check to ensure...

Page 10: ...e first 12 Lift the Track N B You may need assistance from another person and steps to reach and hook one end on to the Support Post Pins 13 Extend or contract the Track to fit between the two Support...

Page 11: ...the use of Easy Fit System do not bump or lean against the posts This might cause the system to become unstable In places where more than one operator will be responsible for using the Easy Fit System...

Page 12: ...ee of obstacles If problem persists contact your local authorised dealer immediately 3 Check that the mater is in the Green Safe zone Lever is not engaged with magnet 1 Support Post assembly instructi...

Page 13: ...ess in the Red button all the way so that safety lock can be engaged 2 Contact local authorized dealer immediately Difficult to insert top and bottom foot into post assembly 1 Top post spacer damaged...

Page 14: ...n the green safe zone see fig 5a below Ensure that both side support assemblies are completely vertical from all directions see fig 5b below The trolley moves easily along the track The top plate and...

Page 15: ...the cloth is damp before the cleaning process DO NOT use a wet cloth over electrical systems Be careful not to let water ingress into the device as although the device is IP rated it is not water tigh...

Page 16: ...Mycrobactericidal Clean 1000 1 litre 1 15 minutes Dirty 5000 1 litre 5 15 minutes Virucidal Clean 500 2 litre 1 5 minutes Dirty 1000 1 litre 1 5 minutes Sporcidal C Diff Clean 1000 1 litre 1 10 minute...

Page 17: ...ene Measures Handle in accordance with good industrial hygiene and safety practice Remove and wash contaminated clothing before re use Wash face hands and any exposed skin thoroughly after handling Co...

Page 18: ...and repairs Ensure that the service record is signed and dated each time it is used Be sure to have this piece of equipment serviced on a regular basis 6 monthly where LOLER applies Purchase Informati...

Page 19: ...Rights 1 All equipment supplied as new against failure within the period of 1 year from date of purchase by virtue of defects in material or workmanship 2 This guarantee does not apply to failure attr...

Page 20: ...s Park Jubilee Way Grange Moor Wakefield West Yorkshire WF4 4TD Email info prismmedical co uk Tel 44 0 1924 840 100 Fax 44 0 844 980 2261 Part Number 999001 Rev A Date Sept 2018 Disclaimer While every...

Reviews: