background image

 

 

 

Section

 

2

   

 

 

 

 

 

Safety

 

Instructions

 

 

 

 

THIS

 

APPLIANCE

 

IS

 

FOR

 

USE

 

WITH

 

PROPANE

 

OR

 

NATURAL

 

GAS

 

ONLY.

 

AT

 

NO

 

TIME

 

ARE

 

SOLID

 

OR

 

ALTERNATIVE

 

FUELS

 

TO

 

BE

 

USED

 

WITH

 

THIS

 

APPLIANCE.

 

 

WARNING

 

 

Before

 

installing

 

this

 

product,

 

read

 

and

 

follow

 

all

 

warning

 

notices

 

and

 

instructions

 

provided.

 

Failure

 

to

 

do

 

so

 

may

 

result

 

in

 

serious

 

injury,

 

property

 

damage

 

and/or

 

death.

 

For

 

additional

 

product

 

reference

 

and

 

copies

 

of

 

these

 

instructions,

 

visit

 

our

 

website

 

at

     

prismhardsacapes.com

 

This

 

product

 

must

 

be

 

installed

 

and

 

serviced

 

by

 

a

 

contractor

 

or

 

qualified

 

installer

 

who

 

is

 

licensed

 

and/or

 

certified

 

within

 

the

 

jurisdiction

 

where

 

the

 

product

 

will

 

reside.

 

In

 

the

 

event

 

no

 

such

 

state

 

or

 

local

 

requirement

 

exists,

 

the

 

installer

 

or

 

maintainer

 

must

 

be

 

a

 

qualified

 

professional

 

with

 

sufficient

 

experience

 

in

 

installation

 

and

 

maintenance

 

of

 

gas

 

and/or

 

electric

 

appliances.

 

Prior

 

to

 

installation,

 

read

 

and

 

follow

 

all

 

warning

 

notices

 

and

 

instructions

 

provided

 

with

 

this

 

product.

 

Failure

 

to

 

do

 

so

 

may

 

result

 

in

 

property

 

damage,

 

personal

 

injury,

 

and/or

 

death.

 

Improper

 

installation

 

and/or

 

operation

 

may

 

result

 

in

 

exposure

 

to

 

carbon

 

monoxide

 

and

 

flue

 

gases

 

which

 

can

 

cause

 

serious

 

injury,

 

property

 

damage,

 

and/or

 

death.

 

For

 

installations

 

in

 

the

 

vicinity

 

of

 

occupied/living

 

areas,

 

Prism

 

Hardscapes

 

strongly

 

recommends

 

installation

 

of

 

carbon

 

monoxide

 

detectors

 

within

 

reach

 

of

 

this

 

appliance

 

and

 

in

 

any

 

adjacent

 

occupied

 

spaces.

 

Improper

 

installation

 

and/or

 

operation

 

will

 

void

 

warranty.

 

Do

 

not

 

store

 

or

 

use

 

gasoline

 

or

 

other

 

flammable

 

vapors

 

and

 

liquids

 

within

 

the

 

vicinity

 

of

 

this

 

or

 

any

 

other

 

appliance.

 

WHAT

 

TO

 

DO

 

IF

 

YOU

 

SMELL

 

GAS

 

 

Immediately

 

switch

 

off

 

main

 

gas

 

supply.

 

 

Do

 

not

 

try

 

to

 

light

 

any

 

appliance.

 

 

Do

 

not

 

touch

 

any

 

electrical

 

switch;

 

do

 

not

 

use

 

any

 

phone

 

near

 

unit.

 

 

Immediately

 

remove

 

yourself

 

from

 

the

 

area,

 

call

 

your

 

gas

 

supplier

 

and

 

follow

 

their

 

instructions.

 

 

If

 

you

 

cannot

 

reach

 

your

 

gas

 

supplier,

 

call

 

the

 

fire

 

department.

 

Installation

 

and

 

service

 

must

 

be

 

performed

 

by

 

a

 

qualified

 

installer,

 

service

 

agency

 

or

 

gas

 

supplier.

 

Summary of Contents for Cilindro

Page 1: ......

Page 2: ...eneral Description 1 1 Receiving Checklist 1 2 Product Dimensions 1 3 Product Contents 1 4 Safely Moving Unit Section 2 Safety Instructions Section 3 Installation Details 3 1 Gas Requirements 3 2 Inte...

Page 3: ...perwork on crate pallet 3 Open top of crate pallet and inspect unit for damage If damaged please notify carrier immediately and sign damaged or do not receive Please also notify Prism Hardscapes offic...

Page 4: ......

Page 5: ...r Pan 1 1 2 Female to Male Orifice 1 1 2 Female to Flare Male Inlet Pipe 1 1 2 Flex Line Hose 1 Propane Gas Hose For Propane Gas Units Only 1 1 2 Flare 2 1 2 Ball Valve 1 Chrome Plated Cover 1 1 1 4 x...

Page 6: ...ASED STABILITY WHILE MOVING USE DOLLY TO NAVIGATE THE UNIT TO THE FINAL POSITION CAREFULLY REMOVE UNIT FROM CRATE AND PLACE ONTO MOVING DOLLY PLACE FIRE FEATURE WITH BASE DOWN TO MOVE PLACE FIRE FEATU...

Page 7: ...and instructions provided with this product Failure to do so may result in property damage personal injury and or death Improper installation and or operation may result in exposure to carbon monoxid...

Page 8: ...se fire feature in windy conditions Do not touch hot surfaces hot media rocks glass etc or open flames Do not reach jump or walk across unit media or open flames Do not ignite fire feature when media...

Page 9: ...to fire feature Once you have created a trench underground for your pipe the stubbed out end should be fitted with a NPT ball valve shutoff rated for gas usage and a flare fitting sized for the same...

Page 10: ...h do not hand tighten An additional flex hose will be attached to the other end of the key valve to the flare fitting at the bottom of the burner The arrow on the key valve should be pointing the dire...

Page 11: ...ly use the recommended amount of media in your unit the amount provided overfilling may result in smaller flame and gas buildup which may cause an explosion Fresh air must be able to pass through the...

Page 12: ...obstruct any vents on lower and upper parts of the fire feature These are designed to ensure proper combustion and ensure no buildup of residual gases within the unit 4 1 3 Electronic Ignition Prism...

Page 13: ...to Fix Improper Gas Pressure Propane Gas Units Check if tank is low or empty may need to be refilled or replaced Natural Gas Units Have a gas professional confirm gas pressure Improperly Applied Fire...

Page 14: ...ry by emailing tech support prismhardscapes com UNIT PRODUCING UNWANTED ODORS Possible Cause How to Fix Gas Leak DO NOT OPERATE Turn off key valve but leave gas source on open The gas should be flowin...

Page 15: ...unit Prism Hardscapes will not be responsible for any defects resulting from misuse user error installation error abuse repair or alteration The use of wood or fuels other than those specified for use...

Page 16: ......

Reviews: