background image

 

 

 

operation.

 

Push

 

knob

 

inward

 

and

 

turn

 

counter

 

clockwise

 

all

 

the

 

way

 

back

 

to

 

the

 

12:00

 

starting

 

position.

 

If

 

the

 

knob

 

does

 

not

 

turn

 

the

 

system

 

off,

 

contact

 

your

 

gas

 

professional

 

to

 

replace

 

gas

 

valve.

 

Only

 

use

 

factory

 

approved

 

parts

 

for

 

replacement.

 

Once

 

burner

 

lights,

 

immediately

 

remove

 

your

 

hand

 

and

 

allow

 

burner

 

to

 

operate

 

for

 

a

 

few

 

minutes

 

before

 

turning

 

the

 

knob

 

all

 

the

 

way

 

back

 

to

 

the

 

12:00/off

 

position.

 

You

 

are

 

now

 

ready

 

to

 

place

 

the

 

fire

 

media

 

onto

 

the

 

burner

 

pan.

 

Slowly

 

pour

 

media

 

onto

 

pan

 

and

 

spread

 

evenly.

 

Fire

 

media

 

should

 

be

 

sparsely

 

spread

 

out

 

enough

 

to

 

cover

 

pan.

 

Only

 

use

 

the

 

recommended

 

amount

 

of

 

media

 

in

 

your

 

unit

 

(the

 

amount

 

provided),

 

overfilling

 

may

 

result

 

in

 

smaller

 

flame

 

and

 

gas

 

buildup

 

which

 

may

 

cause

 

an

 

explosion.

 

Fresh

 

air

 

must

 

be

 

able

 

to

 

pass

 

through

 

the

 

unit.

 

Do

 

not

 

block

 

or

 

obstruct

 

any

 

vents

 

on

 

lower

 

and

 

upper

 

parts

 

of

 

the

 

fire

 

feature.

 

These

 

are

 

designed

 

to

 

ensure

 

proper

 

combustion

 

and

 

ensure

 

no

 

buildup

 

of

 

residual

 

gases

 

within

 

the

 

unit.

 

4.1.3

 

Electronic

 

Ignition

 

Prism

 

Hardscapes

 

offers

 

a

 

separate

 

installation

 

guide

 

for

 

the

 

Electronic

 

PH

Ignite

 

System.

 

All

 

other

 

electronic

 

system

 

guides

 

must

 

be

 

requested

 

from

 

their

 

corresponding

 

manufacturers.

  

      

CAUTION:

 

Open

 

flames

 

will

 

ignite

 

combustible

 

materials

 

such

 

as

 

clothing,

 

fabric,

 

hair,

 

etc.

 

which

 

may

 

result

 

in

 

serious

 

injury,

 

property

 

damage

 

and/or

 

death.

 

Be

 

cautious

 

of

 

the

 

open

 

flames

 

while

 

burner

 

is

 

lit.

 

4.2

 

Adjustment

 

Allow

 

the

 

fire

 

feature

 

and

 

media

 

to

 

cool

 

down

 

before

 

moving

 

or

 

adjusting.

 

This

 

may

 

take

 

from

 

30

 

minutes

 

to

 

1

 

hour

 

depending

 

on

 

the

 

size

 

of

 

the

 

fire

 

feature.

 

Any

 

shifting

 

of

 

fire

 

media

 

or

 

feature

 

should

 

be

 

done

 

after

 

the

 

entire

 

unit

 

has

 

cooled.

 

Also

 

prior

 

to

 

movement,

 

ensure

 

that

 

all

 

gas

 

valves

 

are

 

completely

 

closed

 

and

 

disconnected.

  

Refer

 

to

 

Section

 

1.4

 

for

 

instructions

 

on

 

how

 

to

 

safely

 

move

 

your

 

unit.

 

 

 

 

 

 

 

Summary of Contents for Cilindro

Page 1: ......

Page 2: ...eneral Description 1 1 Receiving Checklist 1 2 Product Dimensions 1 3 Product Contents 1 4 Safely Moving Unit Section 2 Safety Instructions Section 3 Installation Details 3 1 Gas Requirements 3 2 Inte...

Page 3: ...perwork on crate pallet 3 Open top of crate pallet and inspect unit for damage If damaged please notify carrier immediately and sign damaged or do not receive Please also notify Prism Hardscapes offic...

Page 4: ......

Page 5: ...r Pan 1 1 2 Female to Male Orifice 1 1 2 Female to Flare Male Inlet Pipe 1 1 2 Flex Line Hose 1 Propane Gas Hose For Propane Gas Units Only 1 1 2 Flare 2 1 2 Ball Valve 1 Chrome Plated Cover 1 1 1 4 x...

Page 6: ...ASED STABILITY WHILE MOVING USE DOLLY TO NAVIGATE THE UNIT TO THE FINAL POSITION CAREFULLY REMOVE UNIT FROM CRATE AND PLACE ONTO MOVING DOLLY PLACE FIRE FEATURE WITH BASE DOWN TO MOVE PLACE FIRE FEATU...

Page 7: ...and instructions provided with this product Failure to do so may result in property damage personal injury and or death Improper installation and or operation may result in exposure to carbon monoxid...

Page 8: ...se fire feature in windy conditions Do not touch hot surfaces hot media rocks glass etc or open flames Do not reach jump or walk across unit media or open flames Do not ignite fire feature when media...

Page 9: ...to fire feature Once you have created a trench underground for your pipe the stubbed out end should be fitted with a NPT ball valve shutoff rated for gas usage and a flare fitting sized for the same...

Page 10: ...h do not hand tighten An additional flex hose will be attached to the other end of the key valve to the flare fitting at the bottom of the burner The arrow on the key valve should be pointing the dire...

Page 11: ...ly use the recommended amount of media in your unit the amount provided overfilling may result in smaller flame and gas buildup which may cause an explosion Fresh air must be able to pass through the...

Page 12: ...obstruct any vents on lower and upper parts of the fire feature These are designed to ensure proper combustion and ensure no buildup of residual gases within the unit 4 1 3 Electronic Ignition Prism...

Page 13: ...to Fix Improper Gas Pressure Propane Gas Units Check if tank is low or empty may need to be refilled or replaced Natural Gas Units Have a gas professional confirm gas pressure Improperly Applied Fire...

Page 14: ...ry by emailing tech support prismhardscapes com UNIT PRODUCING UNWANTED ODORS Possible Cause How to Fix Gas Leak DO NOT OPERATE Turn off key valve but leave gas source on open The gas should be flowin...

Page 15: ...unit Prism Hardscapes will not be responsible for any defects resulting from misuse user error installation error abuse repair or alteration The use of wood or fuels other than those specified for use...

Page 16: ......

Reviews: