Summary of Contents for Cilindro

Page 1: ......

Page 2: ...eneral Description 1 1 Receiving Checklist 1 2 Product Dimensions 1 3 Product Contents 1 4 Safely Moving Unit Section 2 Safety Instructions Section 3 Installation Details 3 1 Gas Requirements 3 2 Inte...

Page 3: ...perwork on crate pallet 3 Open top of crate pallet and inspect unit for damage If damaged please notify carrier immediately and sign damaged or do not receive Please also notify Prism Hardscapes offic...

Page 4: ......

Page 5: ...r Pan 1 1 2 Female to Male Orifice 1 1 2 Female to Flare Male Inlet Pipe 1 1 2 Flex Line Hose 1 Propane Gas Hose For Propane Gas Units Only 1 1 2 Flare 2 1 2 Ball Valve 1 Chrome Plated Cover 1 1 1 4 x...

Page 6: ...ASED STABILITY WHILE MOVING USE DOLLY TO NAVIGATE THE UNIT TO THE FINAL POSITION CAREFULLY REMOVE UNIT FROM CRATE AND PLACE ONTO MOVING DOLLY PLACE FIRE FEATURE WITH BASE DOWN TO MOVE PLACE FIRE FEATU...

Page 7: ...and instructions provided with this product Failure to do so may result in property damage personal injury and or death Improper installation and or operation may result in exposure to carbon monoxid...

Page 8: ...se fire feature in windy conditions Do not touch hot surfaces hot media rocks glass etc or open flames Do not reach jump or walk across unit media or open flames Do not ignite fire feature when media...

Page 9: ...to fire feature Once you have created a trench underground for your pipe the stubbed out end should be fitted with a NPT ball valve shutoff rated for gas usage and a flare fitting sized for the same...

Page 10: ...h do not hand tighten An additional flex hose will be attached to the other end of the key valve to the flare fitting at the bottom of the burner The arrow on the key valve should be pointing the dire...

Page 11: ...ly use the recommended amount of media in your unit the amount provided overfilling may result in smaller flame and gas buildup which may cause an explosion Fresh air must be able to pass through the...

Page 12: ...obstruct any vents on lower and upper parts of the fire feature These are designed to ensure proper combustion and ensure no buildup of residual gases within the unit 4 1 3 Electronic Ignition Prism...

Page 13: ...to Fix Improper Gas Pressure Propane Gas Units Check if tank is low or empty may need to be refilled or replaced Natural Gas Units Have a gas professional confirm gas pressure Improperly Applied Fire...

Page 14: ...ry by emailing tech support prismhardscapes com UNIT PRODUCING UNWANTED ODORS Possible Cause How to Fix Gas Leak DO NOT OPERATE Turn off key valve but leave gas source on open The gas should be flowin...

Page 15: ...unit Prism Hardscapes will not be responsible for any defects resulting from misuse user error installation error abuse repair or alteration The use of wood or fuels other than those specified for use...

Page 16: ......