Prio Prio Jet X845 User Manual Download Page 15

15

Regular Use
After the installation use your R.O. unit as you normally would.

If your tank is not full the unit will turn on automatically and fill it up with filtered water. Then 
it will flush the membrane and shut off automatically. If you open the faucet and take some 
filtered water from the tank the pump will turn on automatically to refill the tank again.

For  direct  flow  systems,  just  open  the  filtered  water  faucet.  The  pump  will  turn  on 
automatically and will produce the filtered water flow in real time until you close the faucet. 
At the end of each water production cycle the membrane will be flushed, and then the system 
will shut off automatically.

Please note that R.O. membranes (especially dry ones) need up to 50 hours of active operation 
before they reach peak performance in terms of water flow, recovery and rejection rates.

For your safety and peace of mind please unplug the unit from the electrical outlet and close 
the inlet valve before servicing your R.O. system such as changing the filters or membrane, 
or during vacations.

Summary of Contents for Prio Jet X845

Page 1: ...ide Model X845 External Booster Pump Box with Auto Flush for 50 100GPD Reverse Osmosis Filtration Systems Model X855 External Booster Pump Box with Auto Flush for Direct Flow Tankless Reverse Osmosis...

Page 2: ...cing your water filter system and changing the membrane or filters Do not use the appliance if operating requirements such as water temperature water pressure electrical supply etc are not met Follow...

Page 3: ...debris build up on the membrane outer surface Powerful booster pump increases pressure to radically improve the performance and effectiveness of the R O unit in all three key areas increases filtered...

Page 4: ...d is full The pump is off No action is required Flush 18 s membrane flush is going No action is required Reset idling protection was triggered The pump is off To restore normal operation power cycle t...

Page 5: ...iciency rate less water is treated overall by pre filters and the membrane for each gallon of permeate produced This saves the capacity of pre filters and ensures either less frequent change necessity...

Page 6: ...e auto flush booster pump box unit 20 ft 6 m Water tubing 1 x x union tee quick fitting 1 x union check valve User s guide Installation Notes 1 Install your R O machine first Usually steps include inl...

Page 7: ...valent is still recommended prior to the unit point of entry sediment filter works just fine for this purpose 6 Do not connect the unit to the electrical supply until the Setup is completed IMPORTANT...

Page 8: ...nlet fitting of the unit 2 Insert the supply tubing from the RO unit fitting of the unit into the supply inlet of the membrane housing 3 Insert the filtered water tubing from the filtered water outlet...

Page 9: ...e side outlet union tee tting pre lter s X845 X855 with tank tank valve union tee tting General R O System with Tank Connections from nal pre lter outlet to supply inlet of the membrane from ltered wa...

Page 10: ...drain saddle union tee tting X855 direct ow General Direct Flow R O System Connections from nal pre lter outlet to supply inlet of the membrane from ltered water outlet of the membrane from waste wat...

Page 11: ...O600 tank inlet valve waste water outlet permeate outlet to the tank union tee tting from waste water outlet of the membrane to drain or waste water collection container check valve ltered water fauce...

Page 12: ...outlet permeate outlet R O unit inlet inlet valve drain saddle MOD600 ltered water faucet from inlet valve to R O unit inlet from ltered water outlet of the R O unit from waste water outlet of the R...

Page 13: ...tlet waste water outlet of the membrane side permeate outlet of the membrane center membrane inlet X855 Prio Expert OD360 Direct Flow R O System Connections from nal pre lter outlet to supply inlet of...

Page 14: ...nit s power cord into the electrical outlet wait for water to arrive at the faucet it may take a while water foam and air may be going out of the system wait 2 minutes for more or less steady water fl...

Page 15: ...The pump will turn on automatically and will produce the filtered water flow in real time until you close the faucet At the end of each water production cycle the membrane will be flushed and then th...

Page 16: ...io logo are the trademarks of DWT Deutsche Wassertechnologien GmbH Germany As used herein denotes registered trademark status in Germany only Copyright DWT Deutsche Wassertechnologien GmbH Germany 201...

Reviews: