Item “u=x“ indicates the presence of the UIN1 main power supply and the UIN2 "voltage behind the key" signal 

according to the table: 

 

value 

UIN1 

UIN2

 

u=0 

off 

off

 

u=1 

on 

off

 

u=2 

off 

on

 

u=3 

on 

on

 

 
 

Item “A=a“ indicates the status of the business/private switch. It can only have two values, either "A = 0" (private 

journey) or "A = 3" (business journey). 

 

engprs 

If "engprs = g" has a value "engprs = 1", it indicates that the GPRS feature is enabled in the configuration (but 

does not say anything about whether the APN is set or whether the service is enabled by the SIM card). "engprs = 0" 
means that GPRS configuration is disabled. 

 

alive 

Item ”alive=tt“ shows the set time from switching off the ignition until the unit starts sleeping (transition to low-

power mode). The time interval can be expressed in minutes (eg. "alive = 30m") or hours (eg. "alive = 8h"), "alive = 
none" means prohibited sleeping. 

 

aux 

Item ”aux=app“ indicates the function (application) setting on the service line. An item is listed only when this 

function is set. If the correct activity on this line is detected, the brackets are expanded, indicating the time of this 
activity in seconds, minutes or hours (eg. (5s), (99m), (24h)). If activity has not been detected (from restart or within 
99 hours), "(-)" is displayed. The activity means detecting of data on the line. In case of formatted data, the format 
and the checksum of the received message are also checked. For some features the activity is not checked. 

 

trm 

Item ”trm=app“ indicates same information as ”aux=app“ just for terminal line. 
 

id 

Item ”id=src(t) contains information about the driver's log-in source with the most recent login information. 
 

SN, HW a FW 

These items indicate the following unit information: 
"SN=nnnnnnnnnn" – serial number of the unit  
"HW=h.hh" – hardware type of the unit 
"FW=f.f.f.f" – firmware version of the unit 
 

fms/obd/vwm/off 

This items indicate CAN bus mode settings and examples of recognized information from this bus. The first two 

parameters separated by the "/" character include the type of the bus or the application that is set in the 
configuration. Behind this item, the information you see is different by the settings. There may be information about 
mileage, tank fuel, mileage and time for service, etc. 

 
 

Summary of Contents for VETRONICS 760

Page 1: ...allation guide for telematic unit VETRONICS 760 Princip a s Member of W A G payment solutions a s Hv zdova 1689 2a 140 00 Prague Czech Republic Tel 420 236 089 900 e mail servis princip cz www princip...

Page 2: ...according to ECE Observe the polarity of the supply voltage Power wires must be connected through a fuse max 3A to avoid short circuit Warranty does not apply to cases when a power supply does not me...

Page 3: ...card has a deactivated PIN You can do this on your mobile phone before inserting a micro SIM card into the unit Open the rear plastic cover of the unit and insert the micro SIM card into the holder as...

Page 4: ...6 Connecting a vehicle with 24V supply with disconnector and 12V branch If the vehicle is equipped with a battery disconnector or with a 12V branch consult an appropriate connection with the mobile un...

Page 5: ...g harness contact the manufacturer Incorrect connection may result in injury or damage for which the manufacturer is not liable 4 Placing antennas in the vehicle The unit contains internal GSM antenna...

Page 6: ...y the driver in the vehicle When the unit is activated the LED in the center of the sensor is permanently lit The driver is identified by attaching the Dallas chip to the reader The unit records the c...

Page 7: ...trouble codes directly from CAN bus OBDII connector with CAN bus is mandatory for vehicles in European Union since 2000 for gasoline respectively since 2003 for diesel vehicles Standard 16 pin socket...

Page 8: ...board voltage must be presented on pin No 1 only if the ignition is turned on the on board voltage must be presented on pin No 1 and 12 If the wiring is not correct fix the wiring and check again Aft...

Page 9: ...ry 7 5 Checking unit systems via web interface You can easily diagnose the drive through the web interface which can be found at http diag princip cz 7 6 Checking unit systems using diagnostic SMS Dia...

Page 10: ...the correct activity on this line is detected the brackets are expanded indicating the time of this activity in seconds minutes or hours eg 5s 99m 24h If activity has not been detected from restart or...

Page 11: ...ranty seal has been violated Before sending the unit to repair you can use the telephone consultation with the technician from the service department In many cases a malfunction can be removed remotel...

Page 12: ...12 Princip a s Member of W A G payment solutions a s Hv zdova 1689 2a 140 00 Prague Czech Republic Tel 420 236 089 900 E mail servis princip cz www princip cz Rev 4 september 2018...

Reviews: