background image

542-517revC-EN

15

Printed in USA 10/10 © 2010

Product Holding Bin

DHB2PT Series

Exploded View and Parts List (DHB2PT-27B/-27BCE)

Ref.

Part No.

Description

1

541-833S

Upper Heater Kit (DHB2PT-27B)

541-669S

Upper Heat Assembly (DHB2PT-27BCE)

2

541-832S

Lower Heater Kit (DHB2PT-27B)

541-695S

Lower Heater Assembly (DHB2PT-27BCE)

3

541-724S

Rack Kit

4

155695N-4

Pan (Pkg of 4)

5

541-723E4S

Cover (Pkg of 4)

6

536-802S

Display Overlay Kit

7

541-997S

Timer Bar Kit

8

197-232S

Mounting Foot (Pkg of 4)

9

541-734S

Main PCB Kit

Ref.

Part No.

Description

10

541-719S

Display PCB Kit

11

88-709-2-11S

Speaker Kit

12

541-959S

PCB Audio Interface Kit

13

78-184S

Power Switch

14

88-609S

Power Inlet Connector (DHB2PT-27B)

88-720-01S

Power Inlet Connector (DHB2PT-27BCE)

15

72-200-15S

Power Cord (DHB2PT-27B)

72-230S

Power Cord (DHB2PT-27BCE)

Not Shown*
*

541-734S

Control PCB (DHB2PT-27B)

*

541-735S

Control PCB (DHB2PT-27BCE)

2

2

1

2

15

10

12

14

6

11

9

8

13

7

5

4

3

3

Summary of Contents for DHB2PT Series

Page 1: ...p warranty from an authorized service agency or its sub service agency This warranty is subject to the following exceptions conditions Use of any non genuine Prince Castle parts voids this warranty All labor to be performed during regular work hours Overtime premium the incremental amount will be charged to the customer Damage caused by carelessness neglect and or abuse e g dropping tampering or a...

Page 2: ...eal the base to the counter with food approved sealant C Plug the power cord into the bin and connect the plug into the proper electrical outlet All connections must be in accordance with local electrical codes and any other applicable codes NOTE The electrical receptacle should be a dedicated outlet No other equipment should be operating on the line refrigerators fryers etc D If used plug a Princ...

Page 3: ... when product name is displayed will start timing cycle BKFT Breakfast or REG Regular Menu will be lit depending on pre programmed menu When LED is steady RED load product and press the PAN button 4 If no other pan is active for a product the LED for the first pan loaded will turn from RED to GREEN The LED for the 2nd pan 3rd pan etc loaded will turn from RED to YELLOW An LED timer can be stopped ...

Page 4: ...choice and two other displays will change to up and down arrows and ENTR D Press the UP or DOWN Arrow button to scroll to the desired product choice E Press the MENU ENTER button to select the product choice F Repeat Steps A E as required for other Pan displays Press the PRINCE CASTLE LOGO button to exit the Program Mode NOTE Up to six products may be programmed for each Pan button 1 for each menu...

Page 5: ...played TEMPERATURE DISPLAY NOTE The unit is preset to display temperature in Fahrenheit To display in Celsius press and hold the DOWN Arrow button immediately after turning on the power switch To switch back to Fahrenheit press and hold the UP Arrow button after turning on the power switch UP DOWN ARROW BUTTONS Used with other buttons to scroll through heater and temperature selections PRINCE CAST...

Page 6: ...Use a stand alone temperature meter not supplied Hot surfaces Use caution when taking temperature readings within the shelf WARNING U2 20 U220 A Press the UP or DOWN Arrow button until the temperature displayed matches the reading obtained in Step 2 B Press the PRINCE CASTLE LOGO button to save the temperature value and exit the Calibration Mode 4 A B Selecting Breakfast and Regular Menus There ar...

Page 7: ... button to scroll through the 6 menus Release the MENU ENTER button when the desired menu is displayed 2 When the MENU ENTER button is released all displays will again show PROG A Repeat Steps 2 and 3 as required B Press the PRINCE CASTLE LOGO button to exit the Program Mode and return to the Run Mode NOTE Up to six items one for each menu may be programmed for each PAN button A pan may be set as ...

Page 8: ...ess than the Cook More time plus one minute B Use the UP or DOWN Arrow button to scroll to the desired Hold time When the desired Hold time is displayed press the MENU ENTER button to save the desired Hold time A The display will show PROD TIME ENTR Repeat Steps 2 4 for any other product B Press and release the PRINCE CASTLE LOGO button at any time to exit the Program Mode and return to the Run Mo...

Page 9: ...en the desired product is displayed press the MENU ENTER button to select it The first letter in this case theE will start blinking 2 When all four digits have been changed press the MENU ENTER button to save the new name 4 A To change the blinking E use the UP or DOWN Arrow button to scroll to the desired letter number symbol B When the desired selection is displayed press the PAN button to the l...

Page 10: ...ny time to exit the Program Mode and return to the Run Mode NOTE If the MENU ENTER button has not been pressed to save any changes the program will revert to the original time 3 Set Volume Level A The default setting for the volume level is OFF B Press and hold the PRINCE CASTLE LOGO button then immediately press and hold the MENU ENTER button until the display shows one of the programming menus C...

Page 11: ...PRINCE CASTLE LOGO button to store the new address 4 Available addresses are BIN1 thru BIN9 BINA BINB BINC BIND BINE and BINF IMPORTANT Continue to Step 5 to check the timer address No two timers can have the same address To change the timer address turn the unit power switch off and wait 15 seconds Turn the power switch back on and immediately press and hold the PRINCE CASTLE LOGO button and the ...

Page 12: ...NUGG 30 3 Spicy Chicken SPCY 30 26 French Toast TOST 10 8 Chicken Stars STAR 30 27 Large LRG 20 17 6 Burger SIX 20 17 BBQ Chicken BBQ 20 17 Crispy Chicken CRSP 30 26 Special 1 SPC1 30 3 Special 2 SPC2 30 3 Menu Bkft Down Up Down Up Down Up Down Menu LED CRSP ONIN BBQ SPCY SIX SIX LRG LRG MNU1 Bkft BUR1 BUR1 BUR1 BUR1 BUR2 BUR2 BUR2 BUR2 MNU2 REG CHX1 CHX1 CHX2 CHX2 CHX3 CHX3 WING FISH MNU3 REG CHX...

Page 13: ...y flashes Opn and rEL Temperature is below 75 F Heater inoperable Probe inoperable Relay inoperable Normal display during warmup Test heater resistance 150 2 Ohms Check for open thermocouple wires from probe Replace heater probe assembly Replace power circuit board Display shows HHH for an extended period of time and heater surface temperature is hot Temperature is above 300 F abnormal operation D...

Page 14: ... of 4 4 541 725S Rack Kit 5 536 802S Overlay Kit 6 197 232S Mounting Foot Pkg of 4 7 155695N 4 Pan Pkg of 4 8 78 184S Power Switch 9 88 609S Power Connector Ref Part No Description 10 72 200 15S Power Cord 11 541 959S PCB Audio Interface Kit 12 541 734S Main PCB Kit 13 541 719S Display PCB Kit 14 541 999S Timer Bar Kit Not Shown 541 1000S Auxiliary Timer Bar 88 709 2 11S Speaker 2 2 1 2 10 9 11 12...

Page 15: ... 5 541 723E4S Cover Pkg of 4 6 536 802S Display Overlay Kit 7 541 997S Timer Bar Kit 8 197 232S Mounting Foot Pkg of 4 9 541 734S Main PCB Kit Ref Part No Description 10 541 719S Display PCB Kit 11 88 709 2 11S Speaker Kit 12 541 959S PCB Audio Interface Kit 13 78 184S Power Switch 14 88 609S Power Inlet Connector DHB2PT 27B 88 720 01S Power Inlet Connector DHB2PT 27BCE 15 72 200 15S Power Cord DH...

Page 16: ...S Rack Kit 4 155695N 4 Pan Pkg of 4 5 541 723E4S Cover Pkg of 4 6 541 995S Timer Bar Kit 7 197 232S Mounting Foot Pkg of 4 Note DHB2PT 33B has 4 pans Ref Part No Description 8 541 735S Main PCB Kit 9 541 719S Display PCB Kit 10 88 709 2 11S Speaker Kit 11 541 959S PCB Audio Interface Kit 12 78 184S Power Switch 13 88 609S Power Inlet Connector 14 72 200 15S Power Cord 2 2 1 2 14 9 11 13 10 8 7 12 ...

Page 17: ...hoe Blvd Carol Stream IL 60188 USA Telephone 630 462 8800 Fax 630 462 1460 Toll Free 1 800 PCASTLE www princecastle com Printed in USA 10 10 2010 Prince Castle LLC Product Holding Bin DHB2PT Series Wiring Diagram ...