background image

2. Press and hold the 

SET POINT

 button then

press and hold the 

PRINCE CASTLE

 button for 6

seconds.  The LED indicator next to 

PROG

 will

light to indicate the Program Mode is active.

3. Use the 

UP

 and 

DOWN

 arrow buttons to in-

crease or decrease the setpoint temperature.

4. Press the 

SET POINT

 button to end the Program

Mode and store the setpoint temperature value
(the LED next to 

PROG

 will turn off).  The con-

troller will regulate to the new setpoint tempera-
ture.

5. Repeat Steps 1-4 for remaining heaters.

Programming Timers

1.  Press and hold the 

PROG

 button for 6 seconds.

All six timer displays will change to show 

Prog.

2.   Press the timer button to change.  The timer

button LED will change to yellow and the current
programmed time is displayed.

3.  Press the 

UP

 or 

DOWN

 arrow buttons to set the

time.  Time values below 60 minutes will cause
the 

M:S

 led to light, and time values equal to or

greater than one hour will cause the 

H:M

 led to

light.

4.  Repeat steps 2 and 3 for other timers.  Press the

PROG

 button to store the new values and end

the Program Mode.

545-502revB

                                                                                          

     

Printed i

n

 USA 1/06 © 2006

Summary of Contents for DHB2PT-30

Page 1: ...ged to the customer Damage caused by carelessness neglect and or abuse e g dropping tampering or altering parts equipment damaged in shipment by fire flood or an act of God is not covered under this warranty All problems due to operation at voltages other than that specified on equipment nameplates are not covered by this warranty Conversion to correct voltage is the customer s responsibility This...

Page 2: ... SET POINT The set point temperature is displayed for the selected heaters when this button is pressed during the operating mode The SET POINT LED indicator will be on when the Set point mode is selected Press and hold the Prince Castle button then press and hold the SET POINT button to program the temperature for the selected heater ACTUAL TEMP The actual temperature is displayed for the selected...

Page 3: ...int tempera ture 5 Repeat Steps 1 4 for remaining heaters Programming Timers 1 Press and hold the PROG button for 6 seconds All six timer displays will change to show Prog 2 Press the timer button to change The timer button LED will change to yellow and the current programmed time is displayed 3 Press the UP or DOWN arrow buttons to set the time Time values below 60 minutes will cause the M S led ...

Page 4: ...e press and hold the PROG button then press the UP button Release both button the alarm is set to the high level Press and hold the PROG button then press the DOWN button Release both buttons the alarm is set to the low level CLEANING Caution This bin is not watertight Do not clean with Water Jet Jet Spray Do not immerse the bin with water Caution Before unplugging the power cord make sure the pow...

Page 5: ...1 1 2 2 3 4 5 7 8 9 10 11 12 13 545 502revB 5 Printed in USA 1 06 2006 ...

Page 6: ...e heater probe assembly D Display shows HHH for Temperature is above300 F Diagnostic circuit inoperable Replace an extended period of time abnormal operation Power Circuit Board See B above and heater surface temperature is hot Display shows HHH for Probe is inoperable Check for pinched thermocouple an extended period of time wires from probe Replace heater probe and heater surface assembly temper...

Page 7: ...EL YEL J7 J7 J2 J2 TIMERS 1 6 TIMERS 7 12 SPEAKER SPEAKER CONTROLLER DISPLAY BLU BLU BLU BLU BRN BRN BRN BRN POWER SWITCH POWER CORD GRN YEL THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE J19 YEL J19 BLU 4 3 2 1 4 3 2 1 P3 UPPER A HEATER LOWER A HEATER UPPER b HEATER LOWER b HEATER TC J5 J6 J7 J8 J14 YEL RIBBON CONTROLLER P2 P1 J3 J4 J13 J15...