Prince Castle DHB2PT-30 Operating Instructions Manual Download Page 2

INSTALLATION

1. After you have removed the unit from the carton,

inspect the unit for signs of damage. If there is
damage to the unit:

z

Notify carrier within 24 hours after delivery.

z

Save carton and packing materials for inspection

purposes.

z

Contact the Prince Castle Customer Sales

Department at 1-630-462-8800 to arrange for
a replacement to be sent.

1. Place the bin on a counter and seal its base to

the counter with food-approved sealant.

2. Insert the power cord into a proper voltage

receptacle.  Note: This should be a dedicated
outlet.  No other equipment should be operating
on this line (i.e. fryers, refrigerators, etc.)

3. Install the rack and pan covers into the bin.  Pan

covers are used for pans that hold grilled,
broiled, or baked meat products.  Do not install
the pan cover on pans that hold fried foods.

4. Turn the power switch on.  Allow 30 minutes for

warm-up.

THE TEMPERATURE CONTROL
PANEL

1. Indicators and Displays

Within the four character digital display there are
LED indicators.  The four character digital dis-
play shows the numerical value of the tempera-
ture, and the LED indicators display the follow-
ing:

The LED indicator next to the 

UPR HTR 

(for

the 

UPPER HEATER)

 is on when the tem-

perature being displayed is for the upper
heater.

The LED indicator next to the 

PROG

 is on

when in the Program Mode.

The LED indicator next to the 

LWR

 

HTR

 for

the 

LOWER HEATER

) is on when the tem-

perature being displayed is for the lower
heater.

The LED indicator next to the 

HEAT

 is on

when power is applied to the selected heater.

2. Control Panel buttons and LED indi

cators

SET POINT

: The set-point temperature is

displayed for the selected heaters when this
button is pressed during the operating mode.

The SET POINT LED indicator will be on
when the Set-point mode is selected.  Press
and hold the Prince Castle button then press
and hold the SET-POINT button to program
the temperature for the selected heater

.

ACTUAL TEMP:

 The actual temperature is

displayed for the selected heaters when this
button is pressed during the operating mode
and the ACTUAL LED indicator will be on.

UP ARROW

 and 

DOWN ARROW

: When

pressed in the operating mode, will scroll
through the upper and lower heaters for all
four cavities to display either the actual or
set point temperature.  The LED next to the

UPPER SHELF

 or 

LOWER SHELF

 will be on

to indicate which heater is being selected.
The letters 

A

,

 b, C, 

and 

d ( A & B for 2

Shelf Units)

 are displayed to show the

selected cavity location for the upper and
lower heaters.

When reading the digital display from left-to-right,
the following information is displayed: The 

Upper

 or

Lower

 heater for the 

selected

 

cavity (

A, b,C,or

d

)(A & B for 2 shelf units

, if power is being applied

to the 

heat

er, and if the display temperature is the

ACTUAL

 or 

SET

-

POINT

 temperature.

PROGRAMMING

The temperature adjustment range for a heater is:
OFF, 150

°

F to 225

°

F  (OFF, 65

°

C to 107

°

C ).  The

recommended starting setpoint temperatures are:

190

°

F (88

°

C) for the Upper Shelves.

190

°

F (88

°

C) for the Lower Shelves.

NOTE

: Through testing, these temperatures

may be increased or decreased as long as
the food quality and desired temperature of
the product being tested is maintained.

Programming Set Point Temperatures

1. Press and release the 

UP

 or 

DOWN

 arrow button

until the heater in the cavity to be changed is
selected.

   

545-502revB

Printed i

n

 USA 1/06 © 2006

Summary of Contents for DHB2PT-30

Page 1: ...ged to the customer Damage caused by carelessness neglect and or abuse e g dropping tampering or altering parts equipment damaged in shipment by fire flood or an act of God is not covered under this warranty All problems due to operation at voltages other than that specified on equipment nameplates are not covered by this warranty Conversion to correct voltage is the customer s responsibility This...

Page 2: ... SET POINT The set point temperature is displayed for the selected heaters when this button is pressed during the operating mode The SET POINT LED indicator will be on when the Set point mode is selected Press and hold the Prince Castle button then press and hold the SET POINT button to program the temperature for the selected heater ACTUAL TEMP The actual temperature is displayed for the selected...

Page 3: ...int tempera ture 5 Repeat Steps 1 4 for remaining heaters Programming Timers 1 Press and hold the PROG button for 6 seconds All six timer displays will change to show Prog 2 Press the timer button to change The timer button LED will change to yellow and the current programmed time is displayed 3 Press the UP or DOWN arrow buttons to set the time Time values below 60 minutes will cause the M S led ...

Page 4: ...e press and hold the PROG button then press the UP button Release both button the alarm is set to the high level Press and hold the PROG button then press the DOWN button Release both buttons the alarm is set to the low level CLEANING Caution This bin is not watertight Do not clean with Water Jet Jet Spray Do not immerse the bin with water Caution Before unplugging the power cord make sure the pow...

Page 5: ...1 1 2 2 3 4 5 7 8 9 10 11 12 13 545 502revB 5 Printed in USA 1 06 2006 ...

Page 6: ...e heater probe assembly D Display shows HHH for Temperature is above300 F Diagnostic circuit inoperable Replace an extended period of time abnormal operation Power Circuit Board See B above and heater surface temperature is hot Display shows HHH for Probe is inoperable Check for pinched thermocouple an extended period of time wires from probe Replace heater probe and heater surface assembly temper...

Page 7: ...EL YEL J7 J7 J2 J2 TIMERS 1 6 TIMERS 7 12 SPEAKER SPEAKER CONTROLLER DISPLAY BLU BLU BLU BLU BRN BRN BRN BRN POWER SWITCH POWER CORD GRN YEL THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE THERMOCOUPLE J19 YEL J19 BLU 4 3 2 1 4 3 2 1 P3 UPPER A HEATER LOWER A HEATER UPPER b HEATER LOWER b HEATER TC J5 J6 J7 J8 J14 YEL RIBBON CONTROLLER P2 P1 J3 J4 J13 J15...

Reviews: