540889_PUB_DATE_1_JUL_2011.DOC INSTALLATION, MAINTENANCE AND USER' MANUAL
15
Operation
E43
Voltage Par
Wrong Voltage Range
Selection
Make correct selection
Configuration menu
E80
Time Out Input16
On Hold Signal Failure
Soap Dispensing
System
Full stop + tumble.
Whole cycle
E81
No Reheat
Heating Failure
Full stop + tumble.
Wash Step
(Traceability only)
E82
No Refill
Refill failure
Full stop + request for
Continue
Wash Step
(Traceability only)
E83
Cycle Fail
No successful wash
cycle termination
Info that the wash cycle
has to be repeated.
Abnormal Cycle Termination
(Traceability only)
E85
RTC Low Batt
Real Time Clock, No
Battery or battery low
power
For Info only.
End cycle
(Traceability only)
E300-
E353
MITS ERR
Specific Mitsubishi
Inverter Alarm
Full stop + safety time
Whole cycle
E500-
E525
MEMORY ERR
Memory Error
Full stop + safety time
Any time
E550
TRACEYBILITY
WRITE
Internal memory Error
data for traceability
For Info only
Traceability function, whole
cycle
E551
TRACEYBILITY
FULL
Internal Traceability
memory is full
For Info only
Traceability function, whole
cycle
E600-
E628
SOFTW ERR
Software Error
Full stop + safety time
Any time