background image

www.primusaustralia.com.au • Sales: 1300 555 197

Q:  Will direct shade affect the power output of the solar panel?
A:  Yes, locate the panel in direct sunlight for maximum output.

Q:  Will my solar panel work in cloudy conditions?
A:  Yes, the solar panel will work in low light conditions however the  
 

power output will be reduced as there is less energy collected.

Q:  Should I clean my solar panel?
A:  Yes, removing dust, dirt, bird droppings, etc with warm soapy  
 

water will assist with the solar panels energy collecting 

 performance

Q:  How do I clean the power pack?
A:  Use a mix of warm soapy water, do not use bleach or harsh
 

cleaning chemicals and carefully wipe down all surfaces 

 

avoiding water entering the power pack.

Q:  Can I replace the LED’s?
A:  No, the LED light has a life expectance of 8,000 hours of 
 continuous 

operation.

Suggestions for safe and secure use

Failure to follow these complete instructions and the 
suggestions below may cause system damage and/
or personal Injury.

• 

This controller is only designed for 12V solar charging.

•   The built-in electronic circuit protector keeps the controller away  
 

from overcharging, overfl owing, overloading and short-circuit.

•   Sealed, maintenance free VLRA batteries are highly 
 recommended. 

•   The controller will heat up during use, place in a well-ventilated 
 

location and avoid contact with the controller surface.

•   Keep the ventilation holes on the controller free of dust 
 and 

debris.

•   The battery may produce fl ammable gases, please keep 
 

away from spark or open fl ame, ensure the battery is kept in 

 

a well-ventilated location.

•   Fully charge the battery at least once a month.

•   Do not contact or short circuit the terminals or wires.

•   Please use insulated tools during operation, keep both hands  
 

dry and do not stand on the wet ground.

•   Please follow the security recommendations from the battery  
 

manufacturer. Contact the distributor or the installation 

 

personnel if there is any doubt.

General Disclaimer

In no event shall the manufacturer be liable for any damage or personal 
injury caused by non-compliance to the operating instructions and safety 
suggestions in this brochure. The manufacturer will not bear any 
responsibility for misuse, damage, injury, incorrect installation and/or 
system design as such.

Frequently asked questions

NORMAL VOLTAGE

12V

MAX. CHARGING CURRENT/LOAD CURRENT

1A

CURRENT NATURAL LOSS

5mA

SOLAR MODULE

STC Power

5W

Operating Voltage (Vmp)

17V

Operating Current (Imp)

0.29A

Open Circuit Voltage (Voc)

21.6V

Short Circuit Voltage (Ics)

0.34A

BATTERY

Battery Type

Maintenance Free 
Lead - acid battery

Capacity

12V/5.0AH

DC LAMP

Light Source

12 Super 
Bright LED

Rate Power

0.6W

Rate Voltage

12V

Rate Current

50mA

Luminosity

50Lum

CHARGING TIME
(SOLAR)

Approx. 8 to 10 hours in full sunlight when the
battery is fully discharged

OPERATING TIME

1 lamp

66 Hours

4 lamps

16 Hours

OPERATING TEMPERATURE RANGE

-10~60°C
(-40~122°F)

SPECIFICATIONS

Please note: Specifi cations may change without notice

Troubleshooting and maintenance

TROUBLES

POSSIBLE CAUSES

CORRECTIVE MEASURES

ORANGE LED 
IS NOT 
ILLUMINATED 
WHEN SOLAR 
PANEL IS 
CONNECTED

POWER PACK ON/OFF 
BUTTON IS NOT SET

PRESS BUTTON TO 
“ON” POSITION

SOLAR PANEL IS 
NOT CONNECTED 
CORRECTLY

 

CONNECT TO POWER PACK

SOLAR PANEL NOT 
EXPOSED TO THE SUN

LOCATE IN DIRECT 
SUN LIGHT

LED LIGHTS 
WILL NOT 
OPERATE

POWER PACK ON/OFF 
BUTTON IS NOT SET

PRESS BUTTON TO 
“ON” POSITION

RED LED IS 
ON / POWER PACK 
IS FLAT

CHECK CONNECTIONS 
AND SWITCHES ARE IN 
ON POSITION

CHARGE POWER PACK

LED LIGHTS 
OPERATE FOR 
A SHORT 
TIME ONLY

RED LED IS ON - 
POWER PACK IS LOW 
IN VOLTAGE

LOCATE SOLAR PANEL IN 
DIRECT SUNLIGHT FOR 
MINIMUM OF 8 HOURS

CHECK CONNECTIONS 
AND SWITCHES 

POWER PACK 
WILL NOT 
CHARGE

POWER PACK ON/OFF 
BUTTON IS NOT SET

PRESS BUTTON TO 
“ON” POSITION

CHECK POWER 
PACK CONDITION

IF FAULTY - 
REPLACE BATTERY

CHECK SOLAR 
PANEL OUTPUT 

IF FAULTY - CONTACT 
MANUFACTURER

PRI6578