Primrose Awning Installation Instructions
5
B. Indoor Wall Switch:
Electrical components:
1 x Wall Switch
Your awning will have
5 metres
of
4 core cable
. The cable contains two
separate circuits- one circuit for opening the awning and one for retracting it.
The
4 core cable
from the awning must be connected to the wall switch. Then
run a standard mains cable (3 core cable) from the wall switch. Please refer
to Fig. 3
STEP 6: Ensure the awning is level when fully extended.
The built-in spirit level in the front bar will show you if the front bar is level. The
air bubble should be precisely in the centre. If the awning is not level when
fully extended, adjust the slope of one arm - see Adjusting the Slope (below).
Although level when fully extended, the awning may not be perfectly level
when fully retracted – this is norma
l
.
Adjusting the slope (if required)
The optimum slope angle (approx 10 degrees from the horizontal)
is pre-set at the factory.
It can be adjusted by loosening the 17mm locking nuts on both sides
of the arms and then turning the 13mm jack bolts to the desired angle.
Check the built-in spirit level in the middle on the front bar of the
awning. Damage could result if the front bar isn't horizontal. Securely
tighten the 17mm bolts.
5m (16ft)
of 4 core
cable
Awning
Wall
Wall
Indoor wall switch:
Wired to mains
Figure 3
Figure 4
5m (16ft)
of 4 core
cable
Wall
Wall
5m (16ft)
of standard
3 core cable
Standard
Plug socket
(Plug not included)
Indoor wall switch:
Plugged into socket
Awning
Jack bolt
Arm
Locking nuts