background image

Mounted Dimensions

Clock Type

Width from Wall (A)

Height from Ceiling (B)

Depth of 2 Clocks (C)

Dual 4”

4-digit

21.0”(53.34 cm)

11.0” (27.94 cm)

7.5” (19.05 cm)

Dual 4”

6-digit

N/A*

11.0” (27.94 cm)

7.5” (19.05 cm)

*4” 6-digit clock is not available as wall mount.

11

Classic Series Digital Clock/Timer Install Guide

Summary of Contents for OneVue Classic Series

Page 1: ...e is an intelligent environmental monitoring and managed time solution All other trademarks are the property of their respective owners Copyright 2018 Primex The Primex logo is a registered trademark...

Page 2: ...any form or by any means electronic mechanical or otherwise for any purpose without the prior written permission of Primex About Primex Primex is a leading provider of solutions that automate and main...

Page 3: ...e includes notes cautions and warnings content that highlights important messages Typeface Indicates Note Indicates something important or useful Caution Indicates a command or procedure may have an u...

Page 4: ...sions Classic Series 15 Tilt Bracket Digital Clock Timer Install Classic Series 16 Wall Mount Digital Clock Timer Install Classic Series 18 Flush Mount Digital Clock Timer Install Classic Series 19 Du...

Page 5: ...ting outdoors or in wet areas is an electrical hazard and may damage the equipment while nullifying the warranty l Device is cleanable with a cloth moistened with water or a common disinfectant Be sur...

Page 6: ...d used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this eq...

Page 7: ...Note This equipment marketed in the USA is restricted by firmware to only operation on 2 4G channel 1 11 7 Classic Series Digital Clock Timer Install Guide...

Page 8: ...ity and Radio spectrum Matters ERM Wideband Transmission Systems Data transmission equipment operating in the 2 4GHz ISM band and using spread spectrum modulation techniques Harmonized EN covering ess...

Page 9: ...hernet PoE PoE IEEE 802 3af Compliant Certifications FCC IC CE marked Actual power consumption 12 Watts Class 3 Environment Operating Temperature Range 32 to 95 F 0 to 35 C indoor use only Storage Tem...

Page 10: ...digit 7 31 lbs 3 3 kg 260 mA 8 0 20 32 cm 23 25 59 05 cm 3 7 62 cm Classic Digital Clock Timer Flush mount dimensions Clock Type Weight Max Current Draw Height A Width B Depth C Overall Depth Through...

Page 11: ...A Height from Ceiling B Depth of 2 Clocks C Dual 4 4 digit 21 0 53 34 cm 11 0 27 94 cm 7 5 19 05 cm Dual 4 6 digit N A 11 0 27 94 cm 7 5 19 05 cm 4 6 digit clock is not available as wall mount 11 Cla...

Page 12: ...unters can count from 00 00 00 to 99 59 59 99 hours 59 minutes 59 seconds The display flashes every second and the clock beeps for 3 seconds when 99 59 59 is reached Down counter features l The count...

Page 13: ...DIGITAL CLOCK TIMER INSTALL CLASSIC SERIES Learn how to install and operate a Classic Series Digital Clock Timer...

Page 14: ...ck during device preconfiguration Your OneVue account ID and the settings provided during device preconfiguration are configured into your clocks and each clock is labeled before they are shipped from...

Page 15: ...k Timer Model A B C D E F G H 2 5 4 digit 5 0 10 75 2 5 6 0 0 38 0 63 2 1 8 0 4 9 5 18 2 5 2 5 6 digit 5 0 13 75 2 5 6 0 0 38 0 63 2 1 8 0 4 9 5 18 2 5 4 4 digit 8 0 18 0 3 0 14 0 4 0 9 N A 12 0 4 0 4...

Page 16: ...e tilt bracket to the cover plate screw holes on the junction box The RJ 45 jack for the network cable is on the bottom of the clock timer Most building codes prohibit running network cables through t...

Page 17: ...17...

Page 18: ...2 Anchor How to mount a clock timer to a wall surface 1 Mount the clock timer directly to the wall with two 10 screws and anchors per the Tilt Bracket and Direct Wall Mounting Dimension Specifications...

Page 19: ...unction boxes 4 drywall anchors How to install a flush mount clock timer 1 Cut a 5 4 in 13 71 cm x 14 4 in 36 57 cm wall opening that is between two studs Clearance within the wall should be at least...

Page 20: ...unt one junction box in the center of the opening and flush with the front side of the 2 x 4 Digital timer model mount two junction boxes each to be 1 in 2 54 cm from the center of the opening and flu...

Page 21: ...side of the 2 x 4 4 Remove the clock face plate and set aside 5 Remove the four screws that secure the circuit board 6 Disconnect the circuit board power connector A and timer input connector B 21...

Page 22: ...signated code blue system l Elapsed timer input wire to timer control switch For more information see Timer Control Switch Install on page 26 For more information see Timer Control Switch Install on p...

Page 23: ...k assembly to the junction box using the supplied screws and washers 13 Reconnect the circuit board power cord connector and the timer input connector 14 Refasten the circuit board using the four scre...

Page 24: ...be wall mounted ceiling only Supplied parts 1 Flange 1 Dual mount bracket Hardware necessary to complete installation including anchors screws bolts and nuts Not Supplied Junction box How to install a...

Page 25: ...hers Note To wall mount a 4 in x 4 digit model the bracket tabs are required to be on the bottom 5 For wall mount only knock out power cord break 6 Wire clocks to main power using cord retaining clips...

Page 26: ...e timer control switch is not connected to the timer during shipment The supplied 14 ft 4 3 m Rj11 cable is required to be connected from the timer to the timer control switch The cable length can be...

Page 27: ...l switch The switch buttons and wall plate cover may be cleaned with water or a common disinfectant cleaning solution Be sure to test any cleaning solutions on a small area of the switch before using...

Page 28: ...screwdriver press each hook down to release the clock and pull out to unsnap bottom hinges 4 model from the top of the bracket insert a thin screwdriver into each notch and gently move the screwdrive...

Page 29: ...top of the bracket using a screwdriver press each hook down to release the clock Then pull out to unsnap bottom hinges 4 model from the top of the bracket insert a thin screwdriver into each notch an...

Page 30: ...a manual check in for a Digital Clock Timer 1 Press and release the Reset button Note Classic Series Reset button is located inside the removable top panel The four LED circle segments illuminate in s...

Page 31: ...or consequential damages whether resulting from the use misuse or inability to use this product or from defects in the product Some states do not allow this exclusion or limitation of incidental or co...

Page 32: ...e a service agreement with a Primex Partner they are your primary contact for all Technical Support inquires When contacting Primex Technical Support Make sure you have satisfied the system requiremen...