Primary Mover
Mandeville, LA
Page 19
IMPORTANT:
Install (supplied) Bridon load control valve at
this port of hydraulic cylinder.
Maximum Hydraulic Flow Rate
2 GPM
Port
Maximum Pressure For “Raising” Portion of Cycle
3200 PSI
A
Maximum Pressure For “Lowering” Portion of Cycle 1500 PSI
B
Item Qty. Part Number
Description
1
2
6FJ-9017-6FJ-120”
Hose Assy., 120” x 3/8 Hyd. 4000 Psi.
2
4
6FJ-9017-6FJ-48”
Hose Assy., 48” x 3/8 Hyd. 4000 Psi.
3
1
2404-06-08
Fitting, ½ NPT Male x #6 JIC Male Straight
4
2
6801-06-06-FG
Fitting, #6 SAE Male x #6 JIC Male 90 Degree
5
2
2603-06-06-06-FG
Fitting, #6 JIC Tee
6
2
2501-06-08-FG
Fitting, ½ NPT Male x #6 SAE Male 90 Degree
7
1
06-250-12-3-5
Bridon Load Control
8
1
6404-06-08
Fitting, ½ NPT Male x #6 SAE Female Reducer