5
Manual Air Release
The valve is shipped with a factory set pressure
of 50 psig. The diagram to the left shows a cut
away view of the position of the diaphragm on
the seat.
To adjust the valve to relieve air or gas
downstream:
1. Back off lock nut located beneath the
colour coded handle.
2. Turn handle counter clockwise until
approximately 1 inch of thread is
exposed.
3. At this adjustment, the spring has relieved
all tension from the diaphragm allowing
air or gas to be vented downstream.