s P A 2 3 u s e r g u i d e
1 1
s P e A k e r d i s t
The
SPEAKER DIST
menu allows you to
specify the distance of each speaker from the
listening position, in feet or metres. The SPA23 will
then add delays to each channel to ensure that
the sound from each speaker reaches the listener
at the same time.
You can also add an extra delay to the surround
speakers to make the sound more spacious.
•
Use the
<
and
>
buttons on the remote
control to adjust the distance or delay.
In
GENERAL
mode you can adjust the
distance between 0 and 20 feet (0 and 6m).
Setting
DISTANCE UNITS
to
MS
shows the
calculated delays and allows you to adjust them
directly.
c o n t r o l s e t t i n g s
Allows you to configure hardware settings of the
SPA23.
Option
Description
OSD
TRANSPARENT
Set to
YES
to allow the video
image to show through the
background of the on-screen
display, or
NO
to blank the
video image when the on-screen
display is displayed.
OSD POPUP
Determines what information is
shown on the on-screen display
when changing source.
FULL
shows the same information as
the front panel display,
SIMPLE
shows just the source name, and
OFF
turns it off.
OSD POPUP
TIME
Set to 1-10 sec to determine
how long the on-screen display
stays on the screen.
OSD POPUP
POS.
Position of on-screen display.
VFD
BRIGHTNESS
1-3 to specify the front panel
display brightness.
Option
Description
VFD DISPLAY
TIME
Set to 1-10 sec to set the time
before the front panel display
dims.
TRIGGER 1 to
TRIGGER 3
See
Trigger settings below.
REMOTE
SELECT *
Select
FRONT
to use an infra-
red remote control pointer at
the front panel, or
BACK
to
control the SPA23 using the IR
input on the back panel.
FRONT PANEL Select
LOCKED
to lock the
front panel; you will then only
be able to operate the SPA23
via the remote control. Reset to
UNLOCKED
when you turn
off the SPA23 at the back panel.
* Note:
After changing this option you will not
be able to use the remote control to control the
SPA23. To reset this option operate the menus
from the front panel.
Trigger settings
For each trigger you can set the following:
Option
Description
TRIGGER 1-3
Specifies when the current
trigger is active:
OFF
,
STANDBY
to enable it when
the SPA23 is in standby,
INPUT
S
to take the setting from the
INPUT SETTING
menu, or
ZONE 2
to take the setting
from the
ZONE 2
menu.
TRIGGER 1-3
ON DELAY
Allows you to specify a delay
of 0, 1, 2, or 5 secs before the
trigger is activated.
Z o n e 2
For each input the
ZONE 2 SETTINGS
menu
allows you to specify an analogue audio input to
be output to the Zone 2 output.
Option
Description
INPUT
Select one of the 15 inputs to
be configured.
AUDIO
Allows you to specify an
analogue audio input to be
output to the Zone 2 output.
TRIGGER 1-3
Zone 2 trigger settings; see
Trigger settings on this page.
VOLUME
Allows you to set the current
Zone 2 volume (0 to 99).
VOLUME
DEFAULT
Determines the default Zone
2 volume (0 to 99) when
the SPA23 is turned on from
standby.