background image

8

US

CONTROLS

Functions:
ON/OFF 

The unit is switched on and off by pressing the ‘ON/OFF’ button. When the 
unit is on, the fan runs in the set speed.

Humidity

Press the ‘HUMIDITY ADJUST’ buttons repeatedly to choose the desired level 
of relative humidity in the area. The corresponding control lights will indicate 
the selected percentage. The ‘CONT’ control light indicates that the unit is 
running continuously, disregarding the relative humidity level in the area.

Note:

 When the desired level of humidity is achieved the compressor will stop 

however, the fan will continue to run for approximately 15 minutes, this will 
clear the heat exchanger of all collected water.

Fan speed

Press the ‘FAN SPEED SELECT’ button to select low or high speed. The cor-
responding control light will indicate this, Lo=low or Hi=high.

Humidity / Temperature display

The digital display will normally show the measured relative humidity in the 
area.

Your Pridiom dehumidifier features a microprocessor based digital control 
system for optimal performance control.
All functions are accessible via the membrane keypad shown below:

US

Humidity

Setting

Display

Humidity

Adjust

Humidity &

Temperature

Display

Timer

Set

Display

Select

On/Off

Select

Fan Speed

Select

Fan Speed

Display

Temperature

Summary of Contents for PGD1080HCW

Page 1: ...PGD800HCW PGD1080HCW US Dehumidifier www pridiom com USER MANUAL ES Deshumidificador...

Page 2: ...a safe place for future reference Before using your dehumidifier for the first time please ensure that it has been standing for 2 hours in it s upright position before it is switched on SAFETY For saf...

Page 3: ...cal cable and an earthed plug Should it be necessary to replace this plug at any time you must use an earthed electrical plug Warning Never operate this appliance if it has a damaged cord or plug If t...

Page 4: ...This condensate water then flows safely into a fixed drain The dried air then passes through a final heat exchanger where it is warmed before it re enters the room area at a slightly elevated temperat...

Page 5: ...ful effects of excess mois ture as soon as it is plugged in and switched on When positioning your Pridiom dehumidifier ensure that it is placed on a level surface Best results are obtained when window...

Page 6: ...supporting bracket with at least 5 screws horizontally to the wall use the appropriate fixings for the type of wall Note the unit is heavy approxi mately 55lbs Hang the unit on the bracket the two to...

Page 7: ...it back and closing the grille DRAINAGE Connecting the permanent outlet Connect the pipe to an outlet tube with the correct diameter Push the other end of the tube into a drain making sure that the t...

Page 8: ...ll stop however the fan will continue to run for approximately 15 minutes this will clear the heat exchanger of all collected water Fan speed Press the FAN SPEED SELECT button to select low or high sp...

Page 9: ...95 F Defrost Control The dehumidifier is equipped with an automatic de icing mode to defrost the refrigeration coil during low temperature operation The compressor is switched off whilst the fan conti...

Page 10: ...3 L 70 pt day Air Flow High Speed 253cfm 253cfm Voltage 115 V 115 V Current 800 F 60 rh 6 1 A 6 6 A Frequency 60 Hz 60 Hz Power 800 F 60 rh 0 63kW 0 72kW Phase 1ph 1ph Dimensions in 19 5 x 12 x 27 19...

Page 11: ...11 US...

Page 12: ...a crear un entorno de calidad Es importante leer estas instrucciones con cuidado antes de instalar y usar su nuevo deshumidificador Gu rdelas en un lugar seguro para futura referencia Antes de usar su...

Page 13: ...miento autorizado En caso contrario se podr a llegar a perder la garant a Su deshumidificador Pridiom viene suministrado con una cable el ctrico y un enchufe con toma a tierra Si hubiera que reemplaza...

Page 14: ...nces se forma segura a un drenaje fijo El aire seco pasa entonces por un intercam biador de calor donde se calienta antes de volver a entrar en la zona de la sala a una temperatura ligeramente elevada...

Page 15: ...eso de humedad tan pronto como se enchufe y se active Cuando coloque su deshumidificador Pridiom aseg rese de que est colo cado sobre una superficie nivelada Los mejores resultados se obtienen cuando...

Page 16: ...te al menos con 5 tornillos horizontalmente a la pared utilice las fijaciones apropiadas para el tipo de pared T ngase en cuenta que la unidad pesa aproximadamente 55lb Cuelgue la unidad de la abrazad...

Page 17: ...arlo y cierre la rejilla Alojamiento L mpielo de forma regular con un trapo h medo y un detergente suave para el hogar Mantenimiento Un ingeniero competente deber realizar las operaciones de mantenimi...

Page 18: ...utos esto eliminar toda el agua recogida del intercambiador de calor Velocidad del ventilador Pulse el bot n de SELECCI N DE VELOCIDAD DEL VENTILADOR para se leccionar la velocidad baja o alta La luz...

Page 19: ...ol de descongelaci n El deshumidificador viene equipado con un modo de descongelaci n au tom tico para descongelar la bobina de refrigeraci n durante la operaci n a baja temperatura El compresor se ap...

Page 20: ...d 253 cfm 253 cfm Voltaje 115 V 115 V Corriente 800 F 60 HR 6 1 A 6 6 A Frecuencia 60Hz 60Hz Potencia 800 F 60 HR 0 63kW 0 72kW Fase monofase monofase Dimensiones 19 5 x 12 x 27 19 5 x 12 x 27 Peso ne...