OHM™ LIGHT USER MANUAL
9
Spigot/Lifting Eye
[1]
28mm Spigot
- used to fix OHM into a 28mm
receiver.
[2]
M12 Lifting Eye
- used to hang OHM from a
single point.
[3]
M12 x 1.5mm, 25mm Long Bolt
- used to bolt
either the Spigot or the Lifting Eye to OHM.
Hanger Assembly
(Used to hang OHM from four points.)
[1]
Mounted Lifting Eye
[2]
Four Cables
[3]
Carabiners
Safety Cable (not provided)
[1]
Safety Cable
- a minimum of one cable MUST be
used when hanging OHM. The length should be as
short as possible to reduce travel distance if the
primary hanging accessory fails.
[2]
Safety Cable Slots
- MUST be used to attach
safety cable(s) by looping through (as shown).
2
3
1
NOTE: tighten M12 bolt to 85Nm (63lbft).
Use minimum 8.8 grade bolt.
3
2
1
Safe Rigging of the
Hanger Assembly:
ensure the four holes
located in each corner of
OHM
are the ONLY
holes used to secure OHM
to the Hanger Assembly.
Ensure the Carabiners are tightened correctly to
secure the cables to OHM through the four holes.
Also ensure the Carabiners are used and tightened
correctly to secure the cables to the hanger
assembly through the four holes.
A
A
2
1
Safe Use of Safety Cables: ensure the two oval
holes located at the top of OHM
are the ONLY
holes used to secure the safety cable(s).
Ensure safety cable(s) are capable of supporting
the load exerted by OHM plus accessories.
2