Prexiso PR500HV Safety Instructions And The User Manual Download Page 9

9

Scan Mode

• 

Turn on the Scan Mode:

(1) Short press       to turn on scan function, the default angle is 15°

(2) Short press       again to turn off scan function.

• 

Scan angle switch:

(1) Short press       to switch the scan angle, followed by loop from

15°->30°->60°->15°.

(2) Short press       to switch the scan angle, followed by loop from

15°->60°->30°->15°.

TILT function

TILT Operation and Reset

• 

Press to turn on the instrument;

            LED is blinking green when the instrument start to leveling.

   Short press       , the 

TILT

 LED will be solid green, the laser is glitter.

• 

After Auto-leveling, the laser starts to rotate.

• 

After Auto-leveling, if the instrument is tilted, it will be warning, the rotation will be    

   stopped, and the laser is kept bright. 

TILT 

LED is solid red.

• 

Press       again, the instrument will reset and enter TILT function again, and 

   re-leveling.

TILT Mode switch

• 

Press       to switch to Auto-leveling Mode in TILT Mode, TILT LED will be off.

Remark:

When the instrument is in Manual Mode, it can not switch to TILT

function; If necessary, please resume to Auto Mode.

Operation in Slope function

Horizontal Slope function:

• 

First to turn on the Manual Mode after the instrument is powered on.

   The           is solid green, and the           is solid red.

   Short press       to enter the slope function, the           LED is solid green       , 

   it indicates the instrument is in X axis manual slope function.

Remark:

(In TILT Mode also need to enter the Manual Mode first, then press to enter the 

slope mode).

•      

/       can control the laser tilt along the X axis.

Summary of Contents for PR500HV

Page 1: ...IMPORTANT Read before Using EN 1 PR500HV SELF LEVELING ROTARY LASER www prexiso eu com WARRANTY LIMITED YEARS 2...

Page 2: ...e product via an app or software A measurement could be triggered at any time Looking directly into the beam with optical aids can be hazardous Do not operate the product in explosion hazardous areas...

Page 3: ...al Up Beam Window Rotary Laser Glass Enclosed Keypad Charging Power Adapter Plug Jack Vertical support dot PARTS DESCRIPTION H I J K L M N 5 8 insert Vertical Down Beam Mains unit charger Plug EU Chin...

Page 4: ...y Needs Recharging Solid Red With POWER LED Solid Green Manual Mode On Auto Leveling Off Blinking Red With POWER LED Blinking Green Out of Compensation Range Solid Green Tilt Warning On Solid Red Tilt...

Page 5: ...on Press this button to clockwise move the laser dot 4 Speed switch button Press this button to switch the laser beam rotating speed from 300rmp 0rpm 600rpm 300rpm 5 Slope 6 Laser dot moving button Pr...

Page 6: ...t has been fully discharged and avoid letting charge for 10 hours at a time Operating with Charging Power Adaptor Laser tool can operate while plugged into charging power adapter Functions and control...

Page 7: ...e stopped the laser will be glitter TILT LED is solid red Press to reset Press to turn off the instrument Horizontal Position Place laser tool down on its bottom Be sure surface is near level Press to...

Page 8: ...the laser dot will anticlockwise motion 2 Press the laser dot will clockwise motion At 0rpm 1 Short press the rotation angle of laser dot is 10 2 Long press the laser dot will rotate at 0 5 1rpm 3 Pre...

Page 9: ...warning the rotation will be stopped and the laser is kept bright TILT LED is solid red Press again the instrument will reset and enter TILT function again and re leveling TILT Mode switch Press to s...

Page 10: ...ent amount are same as X axis The will blinking green when the tile is overrun Release the will be solid green Short press to quit slope function and back to Manual Mode The is off is solid green and...

Page 11: ...Accuracy Check and Calibration 11 Y X X Y A B...

Page 12: ...12 X1 D1 D1 D2 D0 20 m 20 m 1 3 X2 Y1 D2 20m 20m 2 4 2m D1 1m 2m 1m D2 D1 D2 D0 A B A B C E...

Page 13: ...ween the first reference point D1 and the second reference point D2 C3 There is no need to adjust calibration if the distance between reference point D1 and D2 is 2 mm If the distance measured is 2 mm...

Page 14: ...eling Time Rotation Speed Laser Class Laser Wavelength Operating Time Recharging Time Power Supply IP Rating Operating Temperature Range Storage Temperature Range 1 5 mm 30 m 3 mm 30 m 3 mm 30 m 5 10...

Page 15: ...rect this could be caused by use of the laser near plastic or glass windows dirt or obstruction of the beam windows the laser may have fallen over without your knowledge This highlights the importance...

Page 16: ...ay result from a device failure due to poor maintenance or hazardous connections to other devices RoHS compliance This product complies with the directive 2011 65 EU CAUTION The battery must not be di...