Prexiso P70DLI Manual Download Page 4

Prexiso P70DLI

ON

OFF

i

Change the measurement reference

1

2

The system 

default 

measurements 

start at the 

bottom as a 

reference point.

Press button 

to change the 

reference to 

top for 

measurement. 

3

The measurement 
reference will be 
reset when 
recovering the 
system

.

5 sec

3 sec

3 sec

Device is turned 
OFF. 

If the info icon appears with a number, observe the 
instructions in section "Message Codes".
Example:

Switch between 
the following units:

Operations

Switching   ON / OFF

Unit setting

If no key is 
pressed for 
120 sec, the 
device 
switches off 
automatically. 

3

EN

FUNC

UNITS

C/

OFF

IC255

0.000 m
0.00 ft
0 1/16 in
0'00'' 1/16

Summary of Contents for P70DLI

Page 1: ...P70DLI RECHARGEABLE DUAL LASER DISTANCE MEASURE IMPORTANT Read before Using 2 WARRANTY LIMITED YEARS FUNC UNITS C OFF...

Page 2: ...suring Functions 5 Single measuring Continuous measuring Area Volume Pythagoras 2 point Pythagoras 3 point Angle measurement 5 5 5 6 6 7 7 Technical Data Message Codes Care Disposal Warranty 8 8 8 8 8...

Page 3: ...for the product must ensure that all users understand these directions and adhere to them 2 EN FUNC UNITS C OFF ON Measuring Measuring direction switch Clear Off Add Sub Measuring Reference Single mea...

Page 4: ...rement reference will be reset when recovering the system 5 sec 3 sec 3 sec Device is turned OFF If the info icon appears with a number observe the instructions in section Message Codes Example Switch...

Page 5: ...direction starts from the top to the bottom 3 Long press button again to change to measuring in two direction at the same time 3 sec 3 sec 4 The result is shown in the main line and the measured dista...

Page 6: ...Single measuring Target surfaces Measuring errors can occur when measuring to colourless liquids glass styrofoam or semi permeable surfaces or when aiming at hight gloss surfaces Against dark surface...

Page 7: ...e measured distance above Pythagoras 2 point Prexiso P70DLI 6 EN 25 286 m 7 i The result is shown in the main line and the measured distance above 24 352 m3 1 2 3 4 6 Volume Aim laser at first target...

Page 8: ...ser at first target point 3 Aim laser at second target point Perpen dicular to the measuring surface 90 4 Aim laser at third target point 5 The result is shown in the main line and the measured distan...

Page 9: ...ific treatment and waste management can be downloaded from our homepage Warranty The Prexiso P70DLI has two years warranty For further information on this contact your dealer Subject to change drawing...

Page 10: ...e of accessories from other manufacturers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads constru...

Page 11: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installati...

Page 12: ...eam may be hazardous to the eyes Wavelength 620 690 nm Maximum radiant output power for classification 1 mW Pulse duration 400 ps Pulse repetition frequency 320 MHz Beam divergence 0 16 x 0 6 mrad Lab...