Prexiso P70DLI Manual Download Page 2

1

EN

Prexiso P70DLI

Table of Contents

Instrument Set-up ------------------------------ 2

Overview------------------------------------------------
Charge the battery -----------------------------------

 

2
2

Operations ---------------------------------------- 3

Switching ON/OFF -----------------------------------
Unit setting ---------------------------------------------
Change the measurement reference ------------
Change the measuring direction------------------
Addition/subtraction----------------------------------
Clear-----------------------------------------------------

3
3
3
4
4
4

Measuring Functions -------------------------

5

Single measuring-------------------------------------
Continuous measuring------------------------------
Area------------------------------------------------------
Volume--------------------------------------------------
Pythagoras(2-point)----------------------------------
Pythagoras(3-point)----------------------------------
Angle measurement----------------------------------

5
5
5
6
6
7
7

Technical Data -----------------------------------
Message Codes ---------------------------------
Care -------------------------------------------------
Disposal -------------------------------------------
Warranty ------------------------------------------

8
8
8
8
8

Safety Instructions ---------------------------- 

Symbols used -----------------------------------------
Permitted use -----------------------------------------
Prohibited use ----------------------------------------
Hazards in use ---------------------------------------
Limits of use ------------------------------------------
Areas of responsibility  -----------------------------
Electromagnetic Compatibility (EMC) ----------
FCC statement (applicable in U.S.) -------------
Laser classification ----------------------------------
Labelling ------------------------------------------------ 

9

9
9
9
9
9
10
10
10
11
11

Summary of Contents for P70DLI

Page 1: ...P70DLI RECHARGEABLE DUAL LASER DISTANCE MEASURE IMPORTANT Read before Using 2 WARRANTY LIMITED YEARS FUNC UNITS C OFF...

Page 2: ...suring Functions 5 Single measuring Continuous measuring Area Volume Pythagoras 2 point Pythagoras 3 point Angle measurement 5 5 5 6 6 7 7 Technical Data Message Codes Care Disposal Warranty 8 8 8 8 8...

Page 3: ...for the product must ensure that all users understand these directions and adhere to them 2 EN FUNC UNITS C OFF ON Measuring Measuring direction switch Clear Off Add Sub Measuring Reference Single mea...

Page 4: ...rement reference will be reset when recovering the system 5 sec 3 sec 3 sec Device is turned OFF If the info icon appears with a number observe the instructions in section Message Codes Example Switch...

Page 5: ...direction starts from the top to the bottom 3 Long press button again to change to measuring in two direction at the same time 3 sec 3 sec 4 The result is shown in the main line and the measured dista...

Page 6: ...Single measuring Target surfaces Measuring errors can occur when measuring to colourless liquids glass styrofoam or semi permeable surfaces or when aiming at hight gloss surfaces Against dark surface...

Page 7: ...e measured distance above Pythagoras 2 point Prexiso P70DLI 6 EN 25 286 m 7 i The result is shown in the main line and the measured distance above 24 352 m3 1 2 3 4 6 Volume Aim laser at first target...

Page 8: ...ser at first target point 3 Aim laser at second target point Perpen dicular to the measuring surface 90 4 Aim laser at third target point 5 The result is shown in the main line and the measured distan...

Page 9: ...ific treatment and waste management can be downloaded from our homepage Warranty The Prexiso P70DLI has two years warranty For further information on this contact your dealer Subject to change drawing...

Page 10: ...e of accessories from other manufacturers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads constru...

Page 11: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installati...

Page 12: ...eam may be hazardous to the eyes Wavelength 620 690 nm Maximum radiant output power for classification 1 mW Pulse duration 400 ps Pulse repetition frequency 320 MHz Beam divergence 0 16 x 0 6 mrad Lab...

Reviews: