14
P3 ALL AROUND - PRESTO PALLET POSITIONER
Troubleshooting
Troubleshooting Check List
Problem
Possible Cause
Check This
The unit lowers too easily
Not enough air pressure
See set-up procedure pg 8
(too early)
The unit does not lower
Too much air pressure
See set-up procedure pg 8
enough (too late)
The top of the unit rotates
The base frame of the unit may
Move the unit to a level surface or away
from you.
not be level.
install the optional leveling feet.
Excessive “rumble” when
One or more worn or broken
Remove turntable, replace bearings.
top rotating.
bearings under turntable.
Wear on underside
Normal condition caused by No repair necessary.
of turntable.
wear-hardening of metal.
Maintenance
Routine Periodic Maintenance
Every 90 days -
Check for loose hardware and signs of excessive
wear.
Check to be sure that the unit is placed on a
¿UPOHYHOVXUIDFH
The actuation system of the P3 contains cap-
tive air much like an automotive tire and will
lose small amounts of air over time. Therefore,
air may have to be occasionally added to the
system to compensate for the loss.