Presto Lifts ECOA CDL Series Installation, Operation And Service Manual Download Page 8

Page 8

  

        Owner's Manual Presto DXS Series - ECOA CDL & CLT Series

S E C T I O N  3

INSTALLATION

A. UNCRATING AND INSPECTION

Upon receipt of the Double Scissor Lifts, inspect the equip-

ment completely to determine if there is any shipping damage, 

and that the lift is complete.  Presto-ECOA tests and inspects 

every piece of equipment prior to shipment.  If damage is ap-

parent, a freight claim must be filed with the freight company.  

Do Not use the lift if there appears to be any damage.  With 

the lift in a collapsed position, check the following:

NOTICE

Lifts with oversize table tops must not be over extended 

since doing so may disassociate the cylinder base from 

its socket. (See Section 5, Maintenance).

1.  Check for signs of damage especially to the  

     

     electrical and hydraulic components. 

2.  Check all connections for tightness.

3.  Check for any bent or damaged metal parts.

4.  Check base frame for flatness.

NOTICE

When moving the lift, do not attempt to pick it up by the 

table top. The lift should be picked up by its base only.

B. INSTALLING

Before starting, be sure that the electrical system is wired 

and is in full compliance with local electrical codes and ordi-

nances. Read all of the instructions prior to starting the lift.

1. Handle Assembly

Portable lifts have the push handles removed for 

ease of shipping. Handles should be inserted in the 

holders until they bottom out then tighten set screws 

on each holder with an Allen wrench.

2. Floor Installation

Electrical connections must be made according to 

the electrical schematics and information contained 

in Section 3C and in compliance to local codes and 

ordinances.

C. ELECTRICALS

1. The motors on Double Scissor Lifts are special intermittent 

duty motors with high pull up torques. These motors require 

heavier duty electrical controls than standard motors.

2. Wiring circuits must conform to local codes and must be 

installed by a licensed electrician.

3. Lifts are pre-wired at the factory for motor direction and 

performance.

CAUTION!

All wiring must conform to local codes and must be 

performed by licensed electricians.

WARNING!

Do not attempt to modify or change the electrical circuit. 

Any alterations will cause damage to the pump and pos-

sible physical injury. Only authorized personnel should 

service the electrical system.

4. For the XS, DXS or WXS Series Scissor Lifts, a dedicated 

circuit of 20 amps or larger will suffice to operate the lift.

D. HYDRAULICS

1. Use only hydraulic oil for the lift. The lift has been supplied 

with Conoco Super Hydraulic 32. When adding fluid, use only 

the recommended oils. See Table 1.

2. Before using the lift, check the hydraulic oil level and add 

oil if necessary. Check fittings for tightness.  If the plug is not 

installed, you may damage the pump.

NOTICE

Double Scissor Lifts are designed for normal factory en-

vironments. Where below freezing conditions may exist, 

special fluid must be used. Contact Presto-ECOA Lifts 

for further information when freezing conditions exist.

E. TESTING THE LIFT WITH NO LOAD

1. Before testing the lift, clear the area of any loose material. 

Be sure the lift has no obstruction above it or on any side. 

2. Using the controls provided, briefly operate the lift (5-10 

seconds). If the lift begins to rise with a humming sound and 

functions properly, continue to the full upright position.

NOTICE

If the lift does not rise immediately, or there is any op-

erational problem, stop it immediately. Before continu-

ing, check the rotation of the pump and motor and the 

Summary of Contents for ECOA CDL Series

Page 1: ...tion and Service Manual Model Number ___________________________ Serial ________________________________ Date placed in service _____________ IMPORTANT READ CAREFULLY BEFORE INSTALLING OR OPERATING LI...

Page 2: ...resto ECOA Lifts Customer Service Department or go to our website www PrestoLifts com where you will find a complete list of current owner s manuals to print This label part 10095524 is required by Ca...

Page 3: ...peration 9 B Operating Instructions 9 S E C T I O N 5 Maintenance 10 Hazards 10 If the lift will not raise 11 If the lift fails to lower 11 Routine Periodic Maintenance 12 Troubleshooting 13 PARTS QUA...

Page 4: ...to ECOA for further instructions Additional manuals are available upon request or on our web site at www prestolifts com The scissor lift has a nameplate that provides the load capacity ratings serial...

Page 5: ...s instructions Operators Only trained personnel and authorized personnel shall be permitted to operate these lifts Before Operation Before using the device the operator shall have Read and or had expl...

Page 6: ...s use the signal word NOTICE Safety instruction signs use signal words that are specific to the situation DANGER indicates a hazardous situation which if not avoided will result in death or serious in...

Page 7: ...parts and is capable of causing personal injury if proper precautions are not taken Therefore throughout this manual Presto ECOA Lifts have identified certain hazards which may occur in the use of the...

Page 8: ...motors on Double Scissor Lifts are special intermittent duty motors with high pull up torques These motors require heavier duty electrical controls than standard motors 2 Wiring circuits must conform...

Page 9: ...lief valve Do not maintain the up or down button en ergized if the lift fails to move or after it has reached its up or down limits This will cause damage to the pump and controls B OPERATING INSTRUCT...

Page 10: ...y Before working under the lift remove any load from the platform raise the lift and insert the maintenance devices as shown in Figure 1 Do this every time you work under the lift WARNINGS Release of...

Page 11: ...sets with a crane fork truck or blocking from the floor to table top Ensure switch is properly reinstalled any electrical by pass is removed before operating the lift Any final adjustment of limit swi...

Page 12: ...roblems will develop and extensive repairs will be needed Minimum Required Maintenance for Units with High Cycle Package Every 10 000 cycles visually inspect the entire lift Replace all worn or broken...

Page 13: ...s in suction line Down valve may be energized Check wiring to down valve and solenoid in the valve Missing coupling Check to insure the coupling has been installed between the pump and motor as requir...

Page 14: ...Page 14 Owner s Manual Presto DXS Series ECOA CDL CLT Series FIGURE 3 ELECTRICAL DIAGRAM 115 AC...

Page 15: ...Owner s Manual Presto DXS Series ECOA CDL CLT Series Page 15 FIGURE 4 DXS COMPONENTS DIAGRAM...

Page 16: ...Page 16 Owner s Manual Presto DXS Series ECOA CDL CLT Series FIGURE 5 DXS POWER UNIT COMPONENTS...

Page 17: ...th Conoco Super Hydraulic 32 oil This may be replaced by any other good quality oil with 150 SSU at 100 F and rust and oxidation inhibitors and anti wear properties If the lift will be used at ambient...

Page 18: ...Page 18 Owner s Manual Presto DXS Series ECOA CDL CLT Series Figure 7 Labels and Locations...

Page 19: ...We will invoice you when we ship the replacement part then credit you when you return the worn or damaged part and we verify that it is covered by our warranty Labor is not covered under warranty for...

Page 20: ...placement or repair of defective components at its factory or another location at Presto Lifts discretion This is buyer s sole remedy under any such warranty sale agreement or contract Presto Lifts wi...

Reviews: