40
ELECTRICAL FEEDER CABLE
CONNECTION
To connect the supply cable:
- Remove the screws securing the
cover “A” on the rear of the cooker
(fig. 11.1).
- Feed the supply cable through the
cable clamp “D”. The supply cable
must be of a suitable size for the
current requirements of the appliance;
see the section “Feeder cable section”
(fig. 11.1).
- Connect the wires to the terminal
block “B” as shown in the diagram in
figure 11.2; or connect the phase
wires to the terminal block “B” and the
earth wire to the terminal PE as
shown in figure 11.1.
- Take up any slack in the cable and
secure with the cable clamp “D”.
- Replace the cover “A”.
N.B. The earth conductor must be left
about 3 cm longer than the others.
Fig. 11.1
D
B
PE
A
;;;
;;;
;
;
;
;
;
;
;
;
;
;;
N
L
FEEDER CABLE SECTION TYPE
HO5RR-F
230 V
3 x 2,5 mm
2
230 V
PE
N
L
1
(L
2
)
Fig. 11.2
PE Earth
N
Neutral
L
Live