4
APSSECRS LEDZ Owners revA
Programmed Transmitter Notification
As a security precaution each time the vehicle’s ignition is turn on the status LED
light with flash the number of transmitters programmed into the system. This helps
to identify unauthorized transmitters from accessing your vehicle. If you believe an
unauthorized transmitter has been programmed to your system, contact your installing
dealer for assistance.
User Selectable Notification Chirps
System ARM/DISARM chirps can be toggled ON or OFF without entering the
programming feature banks.
1. Turn the ignition ON then OFF.
2. Press and release the valet/programming button 3 times. The system
will respond with 1 chirp for ON or 2 chirps for OFF.
User Selectable LED
This feature will control whether the LED is ON or OFF when the system is Armed/
Locked and can be toggled ON or OFF without entering the programming feature
banks.
1. Turn the ignition ON, OFF, ON, OFF.
2. Press and hold the valet/programming button for 5 seconds. The system
LED will respond with 1 flash for ON or 2 flashes for OFF.
Bypassing The Shock Sensor
The included security shock sensor has two stages of detection, Warn-Away and Full
Trigger. To arm the system and shock sensor press the
button. The system will beep
and the lights wil flash 1 time.
To Arm the system and bypass the Warn-Away detection stage press the
button 2
times within 5 seconds.
To Arm the Alarm the bypass both detection stages press the
button 3 times within 5
seconds.
City Mode
City Mode allows the user to change the sound of the alarm system to make it easily
identified when the alarm is trigger. To enter City Mode press the
button 4 times
within 10 seconds.