128-9364
21 of 28
21
METHOD 2:
Ignition Key In Sense Wire
Closes With Key In Cylinder
1N4002 Diode
1N4002 Diode
Connect To Negative
Remote Start
Safety Shut Down Wire
To Hood Pin Switch
Safety Shut Down
To connect to the key in sensor circuit as shown for method 2:
1) Locate the control wire that connects the drivers door pin switch to the key in sensor switch.
2) Cut this wire and connect the ignition cylinder side to chassis ground.
3) Locate the key in sensor switch wire that connects the chime module to the ignition cylinder .
4) Cut this wire and connect the ignition cylinder side to the Remote Start Negative Safety Shut down
Wire Gray/Black, using a 4002 series diode as shown above.
NOTE:
A second 4002 series diode may be required to maintain the integrity of the hood open, shut
down circuit. If this is the case, it must be installed as shown in the diagram above. The anode
(Non Striped) side must be connected to the Gray/Black wire of the Remote Start Unit. The cathode
(Striped) side must be connected to the hood pin switch. If the hood pin switch is also used for an
alarm trigger input, be certain to use the dual diode set up shown earlier in this manual.
AFTER THE CONNECTION OF THE NEUTRAL START SAFETY WIRE AS
INDICATED IN ANY OF THE PREVIOUS ALTERNATE CONFIGURATIONS, THIS CIRCUIT
MUST BE TESTED FOR PROPER OPERATION.
Retest by following the steps outlined in the NEUTRAL START SAFETY TEST section of the manual.
DOME DELAY LEARN FEATURE:
This unit has the ability to learn the dome light delay time, up to 60 seconds. If the vehicle has delay
interior lights, and you wish to avoid three chirp, defect zone, indication normally associated with this
type of interior light, we suggest you learn the interior light delay.
To learn the light delay, start with all doors closed:
1) Use the transmitter to Lock / Unlock / Lock / Unlock / Lock / Unlock / Lock, the system. The LED
turns on solid to confirm the system entered the learn mode.
2) Immediately open and close the door of the vehicle to initiate the dome delay. The unit will monitor
the door trigger input Positive, (Purple), and Negative, (Brown) when active. When the dome light
turns off, the unit will add 2 seconds then exit the learn mode.
3) The LED will begin flashing the Armed indication indicating the unit has exited the learn mode and is
armed.
Summary of Contents for APS-922E
Page 27: ...128 9364 27 of 28 27 NOTES ...