background image

128-6458

6 of 16

pin harness to terminal 86 of the optional relay added.  Connect terminal 85 of the optional relay added to
chassis ground.  Most vehicles door lock/unlock motor legs rest at ground, and 12 volts to the door
lock/unlock motor legs for operation, if this is the case in the vehicle you are working on, connect the
remaining terminal, 87, to a fused + 12 volt source.  In the rare instance that the vehicle door lock/unlock
motor legs rest at + 12 volts and switches ground to the door lock/unlock motors, connect he remaining
terminal, 87, to chassis ground.
The Red/Black wire provides a pulse ground output when the unlock button of the transmitter is pressed a
second time after disarming.  Because the vehicle you are working on requires a positive pulse from the
factory door lock switch to the factory door lock control relay, you will have to add a relay to invert the output
polarity of this wire.  Connect the Red/Black wire to terminal 86 of the optional added relay.  Connect
terminal 85 & 87 to a fuse + 12 volt source.  Connect terminal 30 to the low current door unlock wire from the
factory door switch to the door unlock control relay.

Resistive Circuits, As Well As 4 Wire Polarity Reversal and 5 Wire Alternating 12 Volt
Door Lock Control Circuits
These applications require the use of additional components which may include relays, fixed resistors, or
for convenience, the AS 9159 Door Lock Interface.  Refer to the AUDIOVOX Door Lock Wiring Supplement
and or the Audiovox fax back service for information on your particular vehicle for properly connecting to
these types of circuits.
COMPLETING THE INSTALLATION
NOTE: 
This unit has the ability to learn the dome light delay time, up to 60 seconds. If the vehicle has delay
interior lights, and you wish to avoid three chirp, defect zone, indication normally associated with this type
of interior light, we suggest you learn the interior light delay.
To learn the light delay, start with all doors closed:
(1) Use the transmitter to Lock / Unlock / Lock / Unlock / Lock / Unlock / Lock, the system.
The LED turns on solid to confirm the system entered the learn mode.
(2) Immediately open and close the door of the vehicle to initiate the dome delay.
The unit will monitor the door trigger input Positive, (Purple), and Negative, (Brown) when active.
When the dome light turns off, the unit will add 2 seconds then exit the learn mode.
(3) The LED will begin flashing the Armed indication indicating the unit has exited the learn mode and is
armed

Antenna Wire : Be sure to extend the thin black antenna wire to it’s full length and cable tie into place
where it cannot be damaged. Avoid wrapping this wire around major, high current wire looms.
Adjusting the Shock Sensor :

 If used, the sensitivity of the pre - detect circuit is automatically set 30%

less sensitive than the full trigger circuit.
Using a small screwdriver, gently turn the adjustment screw fully counterclockwise. ( DO NOT over turn this
screw. Maximum rotation for this adjustment is 270° ). Close the hood and trunk lids, and arm the alarm.
Wait 6 seconds for the accessories trigger zone to stabilize, then firmly strike the rear bumper with the side
of a closed fist considering the amount of force required to break a window.
CAUTION : Never perform this test on the vehicle’s glass, as you may break the window.
Turn the adjustment screw clockwise ( increasing sensitivity ) about ¼ turn and re - test. Repeat this
procedure until the alarm sounds. Ultimately, one firm strike to the rear bumper will cause the alarm to emit
pre - detect warning tones.
WARNING ! Setting the sensitivity too high can cause false alarms due to noise vibrations from passing

trucks and heavy equipment. To decrease sensitivity, turn the adjustment screw counter clock-
wise.

Wire Dressing : Always wrap the alarm wires in convoluted tubing, or with a spiral wrap of electrical tape.
Secure these looms along the routing using cable ties. This will ensure that the alarm wires are not dam-
aged by falling onto hot or sharp moving surfaces in the vehicle.
Operation : Take a few moments to check off the appropriate option boxes in the owner’s manual, and to
fully explain the operation of the system to your customer.
Place the Valet Switch Tag and or the Remote Start Control Switch Tag on their respective switches and

point these out to the customer.

Page 6

Summary of Contents for 1286458

Page 1: ...nds turn ignition Off Short chirp then long chirp First Then On 1 chirp 1 second door locks Press transmitter Lock button to change 2 chirps 3 5 second door locks Press transmitter Lock button to change 3 chirps 1 sec lock dbl 1 sec unlock or Second Press and release the valet switch 2 chirps auto locks off Press transmitter Lock button to change 1 chirp auto locks on or Third Press and release th...

Page 2: ...e siren to the selected location using the screws and bracket provided Hood or Trunk Pin Switch A pin switch is included for use in protecting the hood or trunk or hatchback of the vehicle The switch must always be mounted to a grounded metal surface of the vehicle It is important to select a location where water cannot flow or collect and to avoid all drip gutters on hood and trunk fender walls C...

Page 3: ...DELAYED 300 mA PULSED OUTPUT CHANNEL 3 The dark blue wire pulses to ground via an independent RF channel from the keychain transmitter This is a transistorized low current output and should only be used to drive an external relay coil WARNING Connecting the dark blue wire to the high current switched output of trunk release circuits some remote start trigger inputs will damage the control module C...

Page 4: ...he transmitter button programmed to the receiver s channel 3 By double pressing this the transmitter button this output will become active for 1 second This is a transistorized low current 300 mA output designed to provide an output only when the transmitter is intentionally operated such as is the case with remote start add on modules If you require more than 300mA drive from this output you must...

Page 5: ... to terminal 87a of the optional relay added Connect the green wire of the 3 pin harness to terminal 86 of the optional relay added Connect terminal 85 of the optional relay added to a fused constant 12 volt source Most vehicles door lock unlock motor legs rest at ground and switch 12 volts to the door lock unlock motor legs for operation if this is the case in the vehicle you are working on conne...

Page 6: ...D turns on solid to confirm the system entered the learn mode 2 Immediately open and close the door of the vehicle to initiate the dome delay The unit will monitor the door trigger input Positive Purple and Negative Brown when active When the dome light turns off the unit will add 2 seconds then exit the learn mode 3 The LED will begin flashing the Armed indication indicating the unit has exited t...

Page 7: ...128 6458 7 of 16 Audiovox Electronic Corp 150 Marcus Blvd Hauppauge N Y 11788 128 6458 ...

Page 8: ...e contact sur Marche a suivi de 1 tonalité courte Appuyer sur le bouton 1 du transmetteur pour change 1 tonalité Verrouillage de porte en 1 seconde 1 clignotements Appuyer sur le bouton 1 du transmetteur pour change 2 tonalités Verrouillage de porte en 3 5 secondes Appuyer sur le bouton 1 du transmetteur pour change 3 tonalités Verrouillage de porte en 1 seconde ou déverrouillage 2 X 1 seconde Deu...

Page 9: ...rt fournis CONTACTEURDECAPOTOUDECOFFRE Un contacteur est fournis pour permettre la protection du capot ou du coffre ou berline avec hayon arrière du véhicule Toujours monter le interrupteur sur une surface métallique mise à la masse du véhicule Il est important de choisir un emplacement dans lequel l eau ne peut pas couler ou s accumuler et d éviter toutes les gouttières possibles dans les parios ...

Page 10: ...fil bleu foncé fournit des impulsions de masse par l intermédaire de la voie radiofréquence d un émetteur indépendant de la chaîne porte clés Ce circuit transistorisé fournit une sortie à faible cournat et ne doit s utiliser que pour commander une bobine de relais extérieur AVERTISSEMENT Le module de commande sera endommagé si l on branche le fil bleu foncé sur la sortie commitée à courant fort du...

Page 11: ...is le bouton d émetteur ce rendement deviendra actif pour 1 seconde Le rendement est 300 mA produite transistorisée et bas courante conçu pour fournir l opération seulement quand l émetteur est intentionnellement activé comme est le cas avec la télécommande commencent vers le haut à s ajouter sur des modules Si vous avez besoin de plus courant que ce rendement laisse 300mA alors vous devez ajouter...

Page 12: ...mmutent la masse pour fermer et ouvrir mettez la borne restante 87 à la masse de châssis Le fil Rouge Noir fournit une impulsion négative quand le bouton d ouvrir de l émetteur est actionné deuxième fois après l initiale désarment Reliez le fil Rouge Noir au bas relais courant qui ouvre les portes de véhicule Verrouillage De Porte à 3 Fils Par Impulsion Positive Dans cette application le fil rouge...

Page 13: ...128 6458 13 of 16 THIS PAGE LEFT BLANK INTENTIONALLY ...

Page 14: ...e peut l endommager Eviter d enrouler ce fil autour des faisceaux principaux de fils comportant des courants forts Réglage Du Detecteur De Vibrations La sensibilité du circuit pré détection est automatiquement réglée à 30 de moins que la sensibilité du circuit de déclenchement total À l aide d un petit tournevis faire tourner la vis de réglage avec précaution et à fond en sens inverse des aiguille...

Page 15: ...128 6458 15 of 16 ...

Page 16: ...128 6458 16 of 16 Audiovox Electronic Corp 150 Marcus Blvd Hauppauge N Y 11788 128 6458 ...

Reviews: