Prestige medical Classic Media 210047 User Manual Download Page 8

211846B

Section 7:

 

Additional information

Spares 

Only those spare parts supplied or specified by Prestige 
Medical should be used in the maintenance of the 
autoclave. Use of unauthorised parts will invalidate any 
warranty given and may adversely affect the performance 
and safety of the unit. 

Accessories

 

A range of accessories are available for your autoclave as 
described below.
Contact your supplier for full details.

219720 - Extended basket (210048 Only) 

219708 - Standard basket

219500 - Green silicone sealing gasket 

219258 - Cord set UK 

Warranty 

Prestige Medical shall, in the first 12 months from the date 
of purchase, repair or replace free of charge any parts which 
prove to be defective in workmanship and/or materials.  

Prestige Medical shall not be so liable in the event 
that the purchaser has failed to adhere to the 
instructions contained herein or if the autoclave has 
been abused, interfered with, altered, repaired or 
serviced by any unauthorised party this may also 
result in the protection provided by the equipment 
being impaired. 

This warranty 

excludes

 the gasket, all internal furniture 

and consumables. Consumer’s statutory rights are not 
affected.

Product decontamination

Should the unit require repair, it must be decontaminated 
in accordance with a recognised procedure prior to return 
or on-site repair. A statement of equipment contamination 
status must be available with the product. (Details of a 
suitable procedure are available on request). 

Cleaning materials

 Mild washing up liquid

 Non-abrasive cream cleaner

 Warm water

Approvals

Note: please ask for details of approvals specific to your 
model.
BS 3970 Part 4  

- Pressure vessel only.    

CE mark  

- Medical device derivative.  

EN 61010  

- Product safety. 

PD 5500 

- Pressure vessel

DIN 58946 Part 8  

 -  Type testing for microbiological 

performance

EMC EN50081-1, EN 50082-1, EN 50082-2
ESCHLE  

-  Electrical safety code for hospital 

laboratory equipment

Packaging 

All Prestige Medical packaging materials used are 
recyclable - please dispose of accordingly.

WEEE Statement

(Waste Electrical and Electronic Equipmentrial)

The weee directive places an obligation on all EU-based 
manufacturers and importers to take back electronic 
products at the end of their useful life. 
Prestige Medical Limited accepts its responsibility to 
finance the cost of treatment of redundant WEEE in 
accordance with the specific recycling requirements.

Disposal

The symbol (shown below) is present on all Prestige 
Medical Products, which indicates that the product must 
NOT be disposed of with other waste. Instead it is the 
user’s responsibility to dispose of their waste electrical and 
electronic equipment by handing it overto an approved 
reprocessor, or by returning it to Prestige Medical for 
reprocessing. For more information about where you can 
send your waster equipment for recycling, please contact 
your local city office or Prestige Medical.

8

Summary of Contents for Classic Media 210047

Page 1: ...211846B Classic Media User Manual Portable Steam Sterilizer...

Page 2: ...e of doubt contact Prestige Medical 0086 Prestige Medical Limited East House Duttons Way Shadsworth Business Park Blackburn BB1 2QR Tel 44 0 1254 682 622 Fax 44 0 1254 682 606 www prestigemedical co u...

Page 3: ...erating symbols opposite Controls A Depressurization Valve B Start Cycle Button C Pressure Rise Indicator D Interlock Mechanism Display lights L1 Power On light illuminates GREEN L2 Heating light illu...

Page 4: ...lease the interlock button Close the Depressurization Valve A 3 5 Power on Switch the unit on at the mains Light L1 illuminates GREEN 3 6 Temperature The 121 C temperature is automatically selected wh...

Page 5: ...ressurization Valve A in the open position when placing the lid upside down on a work surface 7 immerse the unit or electrical cord in water when cleaning 8 use abrasive materials or lubricants when c...

Page 6: ...r arrange for a service engineer to visit Fault 3 Sterilization failed to be achieved Light L4 fails to illuminate GREEN and there is no audible buzzer Disconnect from mains then reconnect and repeat...

Page 7: ...13A to BS1362 Rating Models are rated continuously for intermittent use Body Deep drawn aluminium Lid Aluminium Heater Externally surface mounted mechanically fixed electric element Temperature cut ou...

Page 8: ...of equipment contamination status must be available with the product Details of a suitable procedure are available on request Cleaning materials Mild washing up liquid Non abrasive cream cleaner Warm...

Reviews: