22
IR TRANSFER(IR PASS)
1. Currently the camera support NEC code format. For customized with other codes, pls contact us.
2. Once the camera finish power configuration, enable the IR transfer function via sending COM command.
3. Get the targeted remote controller point to the camera IR receiver, press keys on the remote controller, then the
camera will output the received IR code via VISCA IN port.
4. IR Transfer output format: XX XX XX XX FF
5. The camera can save all setting, no need to re-set after power circle.
UVC CONTROL
1. Only run the client software after the USB3.0 camera has completed self-configuration(the IR indicator in blue
color and will not flash); otherwise may casue black video issue.
2. Make sure the USB3.0 camera is recognized by the PC Device Manager.
3
.
Make sure the interval of video format switching more than 3 seconds, otherwise black video maybe caused.
4
.
Make sure the interval of control command sending from the server(via USB) to the camera no less than 250ms.
5
.
Support standard UVC interface.
UVC Property
Corresponded VISCA Command
PU_BACKLIGHT_COMPENSATION_CONTROL
8x 01 04 33 02 FF
PU_BRIGHTNESS_CONTROL
8x 01 04 4D 00 00 0p 0q FF
PU_GAIN_CONTROL
8x 01 04 49 00 00 00 0p FF
PU_SHARPNESS_CONTROL
8x 01 04 42 00 00 0p 0q FF
PU_WHITE_BALANCE_TEMPERATURE_CONTROL
8x 01 04 35 0p FF
CT_ZOOM_ABSOLUTE_CONTROL
8x 01 04 47 0p 0q 0r 0s FF
CT_PANTILT_ABSOLUTE_CONTROL
8x 01 06 02 VV WW 0Y 0Y 0Y 0Y 0Z 0Z 0Z 0Z F
CT_PANTILT_RELATIVE_CONTROL
8x 01 06 01 pp qq rr ss FF
CT_ZOOM_RELATIVE_CONTROL
8x 01 04 07 pp FF
PU_CONTRAST_CONTROL
8x 01 04 53 0p FF
PU_HUE_CONTROL
8x 01 04 54 0p FF
6. Note: different to standard UVC protocol, PU_CONTRAST_CONTROL means 2D noise reduction, not
CONTRAST value; PU_HUE_CONTROL means 3D noise reduction, not HUE
(
chroma
)
value.
XX XX XX XX: Remote Controller Code
FF: End Code