7.1.2 Filling with grease gun filling device
For filling the grease gun with a filling device, the following modifications must be made:
■
■
Loosen the blind plug at the head of the gun, for this, refer to fig. 3.1-1.
■
■
Fasten the filling valve (12 670).
Put the grease gun with the filling nipple on the filling valve of the grease gun filling device and hold it
while exerting a slight counterpressure.
Actuate the filling device and fill the grease gun. During filling, the plunger rod may be pressed out of the
grease gun tube.
Actuate the latch while pulling the plunger rod. Then push the pluger rod back into the tube.
7.2 Making the grease gun ready for operation
Check to ensure that the grease gun head is firmly screwed to the grease gun tube.
In order to remove trapped air, press on the venting valve while the plunger rod is moved forwards.
Keep the venting valve pressed and activate several times the ON switch until the trapped air escapes.
The grease gun is now ready for use.
7.3 Charging the accumulator
When the accumulator is in the device, press the two plastic buttons at the accumulator‘s bottom side to
remove the accumulator.
The grease gun stops when the accumulator is almost empty.
CAUTION
Damage to the product possible
■
■
If the accumulator is completely discharged, there is a risk that the
accumulator will be damaged or destroyed.
The charging process is started when the accumulator is put into the charger and snaps into the retention.
When the accumulator is fully charged (1 - 2 hours), disconnect the charger from the mains and remove
the accumulator.
8. Operation
CAUTION
Excessive pressure may lead to a bursting of the grease gun head and of the
accessories!
■
■
When using the grease gun, use appropriate equipment such as protective
gloves and goggles.
■
■
Put the grease gun with the hydraulic coupler on the grease nipple.
■
■
Activate the ON switch and carry out the greasing operation.
9. Inspection, maintenance and cleaning
■
■
Inspection, maintenance and cleaning work must be carried out by qualified personnel only.
■
■
In general, the accu grease pump only requires very little care or maintenance.