MINI ONE XL - MANUAL
12
www.preservatech.com
PROGRAMMING
After pushing “Programming Button” (H) display will change
to programming mode.
Display will show a list of parameters enabling the user to change certain
ones. Use the slider on the right side of the display to go to the next
parameter.
Parameters which can be changed have a small icon on the
right side of the value. After pressing it, display allows to change this parameter.
External T
Temperature measured by sensor. Read only.
External RH
Relative humidity measured by sensor. Read only.
Rh preset
Target value of RH.
Rh error offset.
Controls RH alarm. RH alarm is activated when measured
RH is larger then the “rh preset” + “Rh error offset” or is
lower then the “rh preset” - “Rh error offset”. Factory
default=10
Internal T
Temperature inside the treatment box. Read only. (Used by
controller)
Air pump control.
Default value:1. Periodically the machine will turn off the air
pump which is part of normal operations. This setting must
be set to 1 in order for the pump to shut off in case of a
malfunction. If this parameter is changed to 0, the air pump
will be always ON. Under normal circumstances, it should
always be set to 1.
Temper. error level
Parameter to control machine. Do not change without
consulting with Preservatech staff.
Temper. Error delay
Parameter to control machine. Do not change without
consulting with Preservatech staff.
Rh zero offset
Allows to offset measured RH value. Client can use it if value
on the machine display is different then on third party
measuring device. Eg. If difference between measurements
is 2%, setting this parameter to 2 will change display by 2.
PID (P,I,D)
Controls PID parameters. Do not change without consulting
with Preservatech staff.
Logging time interval
Time span between logging data. In minutes.